Partial equivalent sound pressure level as an approach to manage irrelevant sounds in environmental noise measurements

Residual sound and unwanted events are known factors affecting the accuracy of environmental noise measurements. ISO 1996-2 provides methods to manage these irrelevant sounds, for example by applying correction factors, but the methods require a degree of knowledge of the irrelevant sounds that is not always practical or possible to obtain when performing long-term measurements with unattended monitoring stations in complex urban soundscapes. While automatic detection of irrelevant sounds provides the required information, it also allows for new approaches not described in ISO 1996-2. In this paper, we discuss a metric called partial equivalent sound pressure level (Partial Leq), calculated after data samples with residual sound and unwanted events are identified automatically and replaced by project-specific values. Our hypothesis is that better estimates of equivalent sound pressure levels (Leq) can be achieved with this metric, compared with the general methods given in ISO 1996-2. Comparisons of results are presented, together with a discussion of applicability of the Partial Leq metric and experiences gathered from its use.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3239
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial equivalent sound pressure level as an approach to manage irrelevant sounds in environmental noise measurements

Daniela Toledo Helboe, Trond Iver Pedersen
NOISE-CON proceedings
Acoustic Wave Phenomena Research
article

Partial equivalent sound pressure level as an approach to manage irrelevant sounds in environmental noise measurements

Daniela Toledo Helboe, Trond Iver Pedersen
article en

Abstract

Residual sound and unwanted events are known factors affecting the accuracy of environmental noise measurements. ISO 1996-2 provides methods to manage these irrelevant sounds, for example by applying correction factors, but the methods require a degree of knowledge of the irrelevant sounds that is not always practical or possible to obtain when performing long-term measurements with unattended monitoring stations in complex urban soundscapes. While automatic detection of irrelevant sounds provides the required information, it also allows for new approaches not described in ISO 1996-2. In this paper, we discuss a metric called partial equivalent sound pressure level (Partial Leq), calculated after data samples with residual sound and unwanted events are identified automatically and replaced by project-specific values. Our hypothesis is that better estimates of equivalent sound pressure levels (Leq) can be achieved with this metric, compared with the general methods given in ISO 1996-2. Comparisons of results are presented, together with a discussion of applicability of the Partial Leq metric and experiences gathered from its use.

NOISE-CON proceedingsVol. 270(9)
Norsonic (Norway) (NO)
Sustainable cities and communities
Openalex Percentile: Top 84%
Acoustic Wave Phenomena Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines