Instrumentation techniques for the measurement of gunfire (Part 3)

This paper is the third in a series concerning near-field measurement of sound pressure from small arms gunfire. It has been long established that exposure to gunfire events can lead to permanent threshold shift for an unprotected shooter. Close to a shooter's ear, the peak sound pressure level from a rifle or pistol can be 155-to-160 decibels with a pulse rise time on the order of ten microseconds. The U.S. Department of Defense has considered two approaches for assessing exposure limits from small arms gunfire - one involves the unweighted peak sound pressure and the other a series of A-weighted sound exposure events integrated to obtain an equivalent eight-hour dose. This dose is then compared to hearing damage risk criteria established for continuous noise signals. The first approach places great demands on the measurement system since the necessary bandwidth extends well into the ultrasonic range, thereby requiring fast slewing from the amplifiers combined with high sampling rates from the digitizer. The second approach requires the A-weighting filter to have specified time and frequency domain properties in the ultrasonic region. The paper discusses some laboratory experiments using actual gunfire signals to simulate the outcome from both approaches.

Authors

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3184
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Instrumentation techniques for the measurement of gunfire (Part 3)

William Murphy, Anthony NASH
NOISE-CON proceedings
Advanced Measurement and Detection Methods
article

Instrumentation techniques for the measurement of gunfire (Part 3)

William Murphy, Anthony NASH
article en

Abstract

This paper is the third in a series concerning near-field measurement of sound pressure from small arms gunfire. It has been long established that exposure to gunfire events can lead to permanent threshold shift for an unprotected shooter. Close to a shooter's ear, the peak sound pressure level from a rifle or pistol can be 155-to-160 decibels with a pulse rise time on the order of ten microseconds. The U.S. Department of Defense has considered two approaches for assessing exposure limits from small arms gunfire - one involves the unweighted peak sound pressure and the other a series of A-weighted sound exposure events integrated to obtain an equivalent eight-hour dose. This dose is then compared to hearing damage risk criteria established for continuous noise signals. The first approach places great demands on the measurement system since the necessary bandwidth extends well into the ultrasonic range, thereby requiring fast slewing from the amplifiers combined with high sampling rates from the digitizer. The second approach requires the A-weighting filter to have specified time and frequency domain properties in the ultrasonic region. The paper discusses some laboratory experiments using actual gunfire signals to simulate the outcome from both approaches.

NOISE-CON proceedingsVol. 270(9)
Openalex Percentile: Top 85%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Instrumentation techniques for the measurement of gunfire (Part 3) — William Murphy, Anthony NASH · NOISE-CON proceedings (2024) | TGRS Research Map | TGRS