Force sensitivity calibration of artificial mastoids

The Standards and Calibration Laboratory (SCL) has set up a system for calibration of artificial mastoids to meet the growing demand for calibration of bone-conduction hearing aids and audiometers in the audiology industry of Hong Kong. An artificial mastoid (or mechanical coupler, as specified in IEC 60318-6) is a device that mimics the mechanical characteristics of the human mastoid (one of the bones of the skull behind the ear). It is basically composed of a dome-shaped structure and a force transducer. This paper mainly illustrates the method for measuring the force sensitivity level (in unit of dB re 1 pC/N) of an artificial mastoid in the frequency range of 125 Hz to 8 kHz. The calibration system has been automated to meet the demand for artificial mastoid calibration services in Hong Kong. This paper describes (i) the method of determining the force sensitivity level of an artificial mastoid, (ii) the measurement model and uncertainty evaluation, and (iii) the measurement results and details of the calibration system.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3202
Primary Topic
Hand Gesture Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Force sensitivity calibration of artificial mastoids

Angus TUNG Kok Keung, Andrew AU Chi Ho, Brenda LAM Hoi Shan
NOISE-CON proceedings
Hand Gesture Recognition Systems
article

Force sensitivity calibration of artificial mastoids

Angus TUNG Kok Keung, Andrew AU Chi Ho, Brenda LAM Hoi Shan
article en

Abstract

The Standards and Calibration Laboratory (SCL) has set up a system for calibration of artificial mastoids to meet the growing demand for calibration of bone-conduction hearing aids and audiometers in the audiology industry of Hong Kong. An artificial mastoid (or mechanical coupler, as specified in IEC 60318-6) is a device that mimics the mechanical characteristics of the human mastoid (one of the bones of the skull behind the ear). It is basically composed of a dome-shaped structure and a force transducer. This paper mainly illustrates the method for measuring the force sensitivity level (in unit of dB re 1 pC/N) of an artificial mastoid in the frequency range of 125 Hz to 8 kHz. The calibration system has been automated to meet the demand for artificial mastoid calibration services in Hong Kong. This paper describes (i) the method of determining the force sensitivity level of an artificial mastoid, (ii) the measurement model and uncertainty evaluation, and (iii) the measurement results and details of the calibration system.

NOISE-CON proceedingsVol. 270(9)
California Institute for Biomedical Research (US), Standards and Calibration Laboratory
Industry, innovation and infrastructure
Openalex Percentile: Top 83%
Hand Gesture Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Force sensitivity calibration of artificial mastoids — Angus TUNG Kok Keung, Andrew AU Chi Ho, et al. · NOISE-CON proceedings (2024) | TGRS Research Map | TGRS