Noise in a UK intensive care unit: a retrospective cohort study

Excessive noise in hospital Intensive care units (ICU) has been associated with adverse health effects and human factor impacts acknowledged to negatively affect both patients and healthcare providers. Aims: Evaluation of the acoustic environment of the Royal Liverpool University Hospital (RLUH) ICU versus WHO and UK guidelines. Methods: Noise measurements were taken from a six-bedded bay within the RLUH ICU between 15th June and 1st July 2022. This audit focussed on noise data > 87dBA, in accordance with the national exposure limit established by UK Noise Regulations. A retrospective review of relevant patients' records was conducted to identify potential noisy events during the audit period. Results: The highest and lowest LAeq value was 77.9 and 63.5dBA, respectively. All LAeq and LAmax noise measurements recorded exceeded recommended guidelines. Noise fell below recommended daytime guidelines less than 1% of the time. The top potential causes of noise were patient repositioning/personal care, medication administration and suctioning. Conclusion: Noise levels in the RLUH ICU considerably exceed national and international guidelines. These findings highlight the need to address noise pollution in the ICU setting. Hospital staff and policy makers should consider implementing strategies and interventions for noise reduction in ICUs.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3119
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noise in a UK intensive care unit: a retrospective cohort study

Alicia Waite, Thomas Hampton, Ava TAHVILI
NOISE-CON proceedings
Noise Effects and Management
article

Noise in a UK intensive care unit: a retrospective cohort study

Alicia Waite, Thomas Hampton, Ava TAHVILI
article en

Abstract

Excessive noise in hospital Intensive care units (ICU) has been associated with adverse health effects and human factor impacts acknowledged to negatively affect both patients and healthcare providers. Aims: Evaluation of the acoustic environment of the Royal Liverpool University Hospital (RLUH) ICU versus WHO and UK guidelines. Methods: Noise measurements were taken from a six-bedded bay within the RLUH ICU between 15th June and 1st July 2022. This audit focussed on noise data > 87dBA, in accordance with the national exposure limit established by UK Noise Regulations. A retrospective review of relevant patients' records was conducted to identify potential noisy events during the audit period. Results: The highest and lowest LAeq value was 77.9 and 63.5dBA, respectively. All LAeq and LAmax noise measurements recorded exceeded recommended guidelines. Noise fell below recommended daytime guidelines less than 1% of the time. The top potential causes of noise were patient repositioning/personal care, medication administration and suctioning. Conclusion: Noise levels in the RLUH ICU considerably exceed national and international guidelines. These findings highlight the need to address noise pollution in the ICU setting. Hospital staff and policy makers should consider implementing strategies and interventions for noise reduction in ICUs.

NOISE-CON proceedingsVol. 270(9)
University of Liverpool (GB), Liverpool School of Tropical Medicine (GB)
Good health and well-being
Openalex Percentile: Top 72%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.