Flanking transmission from structure-borne sound sources in heavyweight buildings over multiple junctions

In many buildings, rooms that contain vibrationally-active machinery are not always adjacent to habitable rooms; hence it is useful to be able to predict vibration transmission over multiple junctions to non-adjacent rooms. In the first version of the European Standard EN 12354 Part 5 (2009) the equivalent vibration reduction index was introduced to account for transmission across multiple junctions. This was removed in the 2023 version but there remains a need for these estimates at the design stage of a building. This paper compares predictions of vibration transmission from a wall to different receiving rooms in a large heavyweight building. The SEA matrix solution is compared with SEA path analysis using different numbers of paths to assess whether path analysis is feasible, and if so, what errors can be expected when using a limited number of paths. An alternative approach to path analysis is to use transmission functions for heavyweight buildings, and an initial assessment is made to see whether these are expected to vary significantly depending on the position in the building.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_2717
Citations
1
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flanking transmission from structure-borne sound sources in heavyweight buildings over multiple junctions

Carl Hopkins
1 citations
NOISE-CON proceedings
Acoustic Wave Phenomena Research
0.18
article

Flanking transmission from structure-borne sound sources in heavyweight buildings over multiple junctions

Carl Hopkins
article en
1 citations

Abstract

In many buildings, rooms that contain vibrationally-active machinery are not always adjacent to habitable rooms; hence it is useful to be able to predict vibration transmission over multiple junctions to non-adjacent rooms. In the first version of the European Standard EN 12354 Part 5 (2009) the equivalent vibration reduction index was introduced to account for transmission across multiple junctions. This was removed in the 2023 version but there remains a need for these estimates at the design stage of a building. This paper compares predictions of vibration transmission from a wall to different receiving rooms in a large heavyweight building. The SEA matrix solution is compared with SEA path analysis using different numbers of paths to assess whether path analysis is feasible, and if so, what errors can be expected when using a limited number of paths. An alternative approach to path analysis is to use transmission functions for heavyweight buildings, and an initial assessment is made to see whether these are expected to vary significantly depending on the position in the building.

NOISE-CON proceedingsVol. 270(11)
University of Liverpool (GB)
Life below water
Openalex Percentile: Top 52%
Acoustic Wave Phenomena Research
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.