Insertion loss of pipe clamps: Quantity for prediction or manufacturer's advertising?

The noise emitted by water conveying pipes as part of sanitary installations is, in most cases, dominated by structure-borne sound transmission. The water flowing through the pipe causes a vibration of the pipe system that is transmitted to the installation wall through pipe clamps. A common mitigation measure is an elastic inlay inside the pipe clamps. Some manufacturers of these clamps advertise the insertion losses determined by non-standardized tests. Recent studies show a high dependency of the insertion loss on the mounting conditions, e.g. how tight are pipes fastened in the clamp. This contribution aims to answer the question of whether and how the mounting condition affects the insertion loss of the pipe clamps and thus how representative the specified values can be for the building situation. The investigations are carried out in-situ on the reception plate and in a building like test stand with an excitation by flowing water as well as with impact hammer excitation. This study is part of a research project with the overall aim to provide source data for the prediction of the sound transmission in buildings using EN 12354-5.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_4069
Primary Topic
QR Code Applications and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insertion loss of pipe clamps: Quantity for prediction or manufacturer's advertising?

Jochen Scheck, Berndt Zeitler, L. Däuble
NOISE-CON proceedings
QR Code Applications and Technologies
article

Insertion loss of pipe clamps: Quantity for prediction or manufacturer's advertising?

Jochen Scheck, Berndt Zeitler, L. Däuble
article en

Abstract

The noise emitted by water conveying pipes as part of sanitary installations is, in most cases, dominated by structure-borne sound transmission. The water flowing through the pipe causes a vibration of the pipe system that is transmitted to the installation wall through pipe clamps. A common mitigation measure is an elastic inlay inside the pipe clamps. Some manufacturers of these clamps advertise the insertion losses determined by non-standardized tests. Recent studies show a high dependency of the insertion loss on the mounting conditions, e.g. how tight are pipes fastened in the clamp. This contribution aims to answer the question of whether and how the mounting condition affects the insertion loss of the pipe clamps and thus how representative the specified values can be for the building situation. The investigations are carried out in-situ on the reception plate and in a building like test stand with an excitation by flowing water as well as with impact hammer excitation. This study is part of a research project with the overall aim to provide source data for the prediction of the sound transmission in buildings using EN 12354-5.

NOISE-CON proceedingsVol. 270(3)
Stuttgart Technical University of Applied Sciences (DE)
Openalex Percentile: Top 73%
QR Code Applications and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Insertion loss of pipe clamps: Quantity for prediction or manufacturer's advertising? — Jochen Scheck, Berndt Zeitler, et al. · NOISE-CON proceedings (2024) | TGRS Research Map | TGRS