Validation of an absorption coefficient measurement technique using two cardioid microphones in any impedance tube

We have proposed a technique for measuring sound pressure and particle velocity using a combination of cardioid microphones and then applied it to obtain the acoustic absorption coefficient in a tube. So far, we have revealed that either using one cardioid microphone measured twice or using a pair of cardioid microphones measured once are both suitable for the measurement and that the calibration of the cardioid microphones is required. If the technique works correctly, this technique holds promise for measuring the acoustic absorption coefficient of various specimens in any tube and with any cardioid microphones. To validate the technique's effectiveness, we conducted experiments in multiple square-section wooden or round-section steel tubes, with specimens of glass wool and polyester terephthalate (PET) wool. As a result, this technique can provide accurate absorption coefficient measurements in any tube configuration.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3830
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an absorption coefficient measurement technique using two cardioid microphones in any impedance tube

Toshiki Hanyu, Kazuma Hoshi
NOISE-CON proceedings
Electrical and Bioimpedance Tomography
article

Validation of an absorption coefficient measurement technique using two cardioid microphones in any impedance tube

Toshiki Hanyu, Kazuma Hoshi
article en

Abstract

We have proposed a technique for measuring sound pressure and particle velocity using a combination of cardioid microphones and then applied it to obtain the acoustic absorption coefficient in a tube. So far, we have revealed that either using one cardioid microphone measured twice or using a pair of cardioid microphones measured once are both suitable for the measurement and that the calibration of the cardioid microphones is required. If the technique works correctly, this technique holds promise for measuring the acoustic absorption coefficient of various specimens in any tube and with any cardioid microphones. To validate the technique's effectiveness, we conducted experiments in multiple square-section wooden or round-section steel tubes, with specimens of glass wool and polyester terephthalate (PET) wool. As a result, this technique can provide accurate absorption coefficient measurements in any tube configuration.

NOISE-CON proceedingsVol. 270(5)
Nihon University (JP)
Affordable and clean energy
Openalex Percentile: Top 85%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.