The frame around a test specimen and its influence on the measured sound absorption coefficient

For most practical cases of reverberation room measurements of sound absorption coefficient according to ISO 354:2003, the standard requires the edges of the test specimen to be covered by a reflective frame. The purpose of this requirement is to keep the edges of the test specimen from absorbing sound. While this statement is consistent with practical measurement results at medium to high frequencies, it has been shown that the low frequency performance of a high-absorbing test specimen worsens when a frame is not in place. To further investigate this phenomenon, a series of reverberation room measurements have been carried out on several variations of a porous absorber test specimen. The goal of the measurements has been to determine whether the size and dimensions of the test specimen affect the test results, and if any such affections are dependent on the presence of a frame. Additionally, the sound absorption area of the frame itself has been measured to elucidate whether the frame is likely to give a significant contribution to the total sound absorption area of a framed test specimen. The results will be presented and discussed in this paper.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_4166
Primary Topic
Mechanical and Thermal Properties Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The frame around a test specimen and its influence on the measured sound absorption coefficient

Gjermund V. HOLøYEN
NOISE-CON proceedings
Mechanical and Thermal Properties Analysis
article

The frame around a test specimen and its influence on the measured sound absorption coefficient

Gjermund V. HOLøYEN
article en

Abstract

For most practical cases of reverberation room measurements of sound absorption coefficient according to ISO 354:2003, the standard requires the edges of the test specimen to be covered by a reflective frame. The purpose of this requirement is to keep the edges of the test specimen from absorbing sound. While this statement is consistent with practical measurement results at medium to high frequencies, it has been shown that the low frequency performance of a high-absorbing test specimen worsens when a frame is not in place. To further investigate this phenomenon, a series of reverberation room measurements have been carried out on several variations of a porous absorber test specimen. The goal of the measurements has been to determine whether the size and dimensions of the test specimen affect the test results, and if any such affections are dependent on the presence of a frame. Additionally, the sound absorption area of the frame itself has been measured to elucidate whether the frame is likely to give a significant contribution to the total sound absorption area of a framed test specimen. The results will be presented and discussed in this paper.

NOISE-CON proceedingsVol. 270(3)
SINTEF (NO), SINTEF Community
Openalex Percentile: Top 83%
Mechanical and Thermal Properties Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The frame around a test specimen and its influence on the measured sound absorption coefficient — Gjermund V. HOLøYEN · NOISE-CON proceedings (2024) | TGRS Research Map | TGRS