Loudness and preference judgments for noises of a heat pump

An increasing number of heat pumps have recently been installed to replace conventional heating systems to provide more environmentally friendly and energy-efficient indoor heating. Most commonly, air-to-water heat pumps are chosen. However, the sounds of their fan and compressor can lead to noise complaints and can reach the limit of noise emission regulations. To achieve a more pleasant environment, research is conducted to reduce the perceived noise of heat pumps. As part of an interdisciplinary research project, this study aims to investigate the annoyance ratings of a heat pump and characterize them in terms of equivalent loudness and preference penalties. The study uses a two-alternative forced-choice (2AFC) method with a 1-up-1-down rule to measure the point of subjective equality for six stimuli representing different operation states of the investigated device. This experiment aims to identify differences between loudness and preference, and combined with an evaluation of psychoacoustic parameters, its results are used to improve the acoustics of heat pumps and the overall user experience.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3589
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Loudness and preference judgments for noises of a heat pump

Lara Stürenburg, Hark Braren, Janina Fels, Lukas Aspöck
1 citations
NOISE-CON proceedings
Building Energy and Comfort Optimization
0.27
article

Loudness and preference judgments for noises of a heat pump

Lara Stürenburg, Hark Braren, Janina Fels, Lukas Aspöck
article en
1 citations

Abstract

An increasing number of heat pumps have recently been installed to replace conventional heating systems to provide more environmentally friendly and energy-efficient indoor heating. Most commonly, air-to-water heat pumps are chosen. However, the sounds of their fan and compressor can lead to noise complaints and can reach the limit of noise emission regulations. To achieve a more pleasant environment, research is conducted to reduce the perceived noise of heat pumps. As part of an interdisciplinary research project, this study aims to investigate the annoyance ratings of a heat pump and characterize them in terms of equivalent loudness and preference penalties. The study uses a two-alternative forced-choice (2AFC) method with a 1-up-1-down rule to measure the point of subjective equality for six stimuli representing different operation states of the investigated device. This experiment aims to identify differences between loudness and preference, and combined with an evaluation of psychoacoustic parameters, its results are used to improve the acoustics of heat pumps and the overall user experience.

NOISE-CON proceedingsVol. 270(6)
RWTH Aachen University (DE)
Openalex Percentile: Top 43%
Building Energy and Comfort Optimization
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.