Experimental study on hydrogen pipeline leakage: Negative pressure wave characteristics and inline detection method

This paper presents an experimental study on a potential safety system for hydrogen fuel cells. It focuses on early leakage detection and localization. This would enable effective system response to avoid the effects of catastrophic loss of containment. Experimental results are presented from a pipeline setup wherein the leak is identified utilizing inline pressure sensors and flowmeters. The investigations involve recorded data at two leak locations at different initial pressures, mass flow rates, and leak diameters. The leak detection technique is based on analysis of the negative pressure wave (NPW) intensity and propagation duration, denoted as peak-to-peak amplitude (Δh) and oscillation period (Δτ). They are extracted from filtered pressure records' first derivative (dp/dt). Δh and Δτ increase as the initial mass flow rate and leak diameter decrease. Therefore, this approach is advantageous for detecting leaks from tiny cross-sections. Δh and Δτ measured at two leak positions at different lengths from the system inlet increase at a higher initial flow rate of 1.0 g/s, but they exhibit opposite behavior at a lower rate (0.42 g/s). Increasing the sampling rate in the dp/dt-time graphs enhances the precision of leak localization. Calculation results show an effective leakage localization with an accuracy of 15 mm (2.5%). The leak flow rate during nitrogen leakage tests is about three times that of hydrogen, and it has higher Δh (about two times at 10 bar). • The feasibility of the negative pressure wave method for leak detection is studied. • The NPW oscillation period and peak-to-peak amplitude are analyzed. • The leak localization calculation shows good accuracy (<2.5%). • H 2 and N 2 have significant differences in leak behavior based on gas properties.

Authors

Institutions

Publication Details

Journal
Journal of Loss Prevention in the Process Industries
Published
2024-10-09
DOI
https://doi.org/10.1016/j.jlp.2024.105452
Citations
7
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
9.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on hydrogen pipeline leakage: Negative pressure wave characteristics and inline detection method

Knut Vaagsaether, Raghav Sikka, Per Morten Hansen, Osama M. Ibrahim et al.
7 citations
Journal of Loss Prevention in the Process Industries
Combustion and Detonation Processes
9.09
article

Experimental study on hydrogen pipeline leakage: Negative pressure wave characteristics and inline detection method

Knut Vaagsaether, Raghav Sikka, Per Morten Hansen, Osama M. Ibrahim, Ji-Yong Shin
article en
7 citations

Abstract

This paper presents an experimental study on a potential safety system for hydrogen fuel cells. It focuses on early leakage detection and localization. This would enable effective system response to avoid the effects of catastrophic loss of containment. Experimental results are presented from a pipeline setup wherein the leak is identified utilizing inline pressure sensors and flowmeters. The investigations involve recorded data at two leak locations at different initial pressures, mass flow rates, and leak diameters. The leak detection technique is based on analysis of the negative pressure wave (NPW) intensity and propagation duration, denoted as peak-to-peak amplitude (Δh) and oscillation period (Δτ). They are extracted from filtered pressure records' first derivative (dp/dt). Δh and Δτ increase as the initial mass flow rate and leak diameter decrease. Therefore, this approach is advantageous for detecting leaks from tiny cross-sections. Δh and Δτ measured at two leak positions at different lengths from the system inlet increase at a higher initial flow rate of 1.0 g/s, but they exhibit opposite behavior at a lower rate (0.42 g/s). Increasing the sampling rate in the dp/dt-time graphs enhances the precision of leak localization. Calculation results show an effective leakage localization with an accuracy of 15 mm (2.5%). The leak flow rate during nitrogen leakage tests is about three times that of hydrogen, and it has higher Δh (about two times at 10 bar). • The feasibility of the negative pressure wave method for leak detection is studied. • The NPW oscillation period and peak-to-peak amplitude are analyzed. • The leak localization calculation shows good accuracy (<2.5%). • H 2 and N 2 have significant differences in leak behavior based on gas properties.

Journal of Loss Prevention in the Process IndustriesVol. 92
University of South-Eastern Norway (NO)
Norges Forskningsråd
Affordable and clean energy
Openalex Percentile: Top 3%
Combustion and Detonation Processes
9.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.