Simultaneous Detection of Clenbuterol and Higenamine in Urine Samples Using Interference-Free SERS Tags Combined with Magnetic Separation

Sports doping remains a significant challenge in competitive sports. Given that urine analysis is the standard for detecting doping, developing rapid, sensitive, accurate, and high-throughput methods for stimulant detection in urine is crucial. Surface-enhanced Raman scattering (SERS) tag-based immunoassays have emerged as powerful analytical tools known for their high sensitivity and specificity, holding particular promise for stimulant detection in urine samples. However, both the Raman signals of typical SERS tags and sample matrices are within the Raman fingerprint region (<1800 cm<sup>-1</sup>), which could lead to spectrum overlap, potentially reducing detection accuracy and sensitivity. By recognizing this, we designed a competitive immunoassay that integrates two types of zero-background SERS tags and magnetic separation. These innovative SERS tags exhibit distinctive Raman peaks within the Raman-silent region (1800-2800 cm<sup>-1</sup>), effectively mitigating potential spectrum overlap with background sample signals. Moreover, magnetic separation not only enhances operational simplicity but also improves the system's anti-interference capability. Using clenbuterol (CL) and higenamine (HM) as model targets, the SERS-based competitive immunoassay demonstrated sensitive detection of individual CL or HM standards, with limits of detection (LODs) of 0.87 and 0.71 pg/mL, respectively. In multiplex mode, CL and HM can be simultaneously detected with LODs of 1.0 and 0.81 pg/mL, respectively. Furthermore, the recovery rates in urine samples ranged from 83 to 116% (relative standard deviation, RSD ≤ 6.4%) for CL and from 82 to 103% (RSD ≤ 5.1%) for HM, further confirming the reliability of the SERS-based immunoassay for practical applications.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-10-09
DOI
https://doi.org/10.1021/acssensors.4c01623
Citations
8
Primary Topic
Pharmacological Effects and Assays
Type
article
Field-Weighted Citation Impact
2.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Detection of Clenbuterol and Higenamine in Urine Samples Using Interference-Free SERS Tags Combined with Magnetic Separation

Yang Lü, Xia Gao, Dingbin Liu, Yaqing Liu et al.
8 citations
ACS Sensors
Pharmacological Effects and Assays
2.73
article

Simultaneous Detection of Clenbuterol and Higenamine in Urine Samples Using Interference-Free SERS Tags Combined with Magnetic Separation

Yang Lü, Xia Gao, Dingbin Liu, Yaqing Liu, Chenyang Sun, Jinru Xiao, Jiacheng Ding, Hongmei Gao
article en
8 citations

Abstract

Sports doping remains a significant challenge in competitive sports. Given that urine analysis is the standard for detecting doping, developing rapid, sensitive, accurate, and high-throughput methods for stimulant detection in urine is crucial. Surface-enhanced Raman scattering (SERS) tag-based immunoassays have emerged as powerful analytical tools known for their high sensitivity and specificity, holding particular promise for stimulant detection in urine samples. However, both the Raman signals of typical SERS tags and sample matrices are within the Raman fingerprint region (<1800 cm<sup>-1</sup>), which could lead to spectrum overlap, potentially reducing detection accuracy and sensitivity. By recognizing this, we designed a competitive immunoassay that integrates two types of zero-background SERS tags and magnetic separation. These innovative SERS tags exhibit distinctive Raman peaks within the Raman-silent region (1800-2800 cm<sup>-1</sup>), effectively mitigating potential spectrum overlap with background sample signals. Moreover, magnetic separation not only enhances operational simplicity but also improves the system's anti-interference capability. Using clenbuterol (CL) and higenamine (HM) as model targets, the SERS-based competitive immunoassay demonstrated sensitive detection of individual CL or HM standards, with limits of detection (LODs) of 0.87 and 0.71 pg/mL, respectively. In multiplex mode, CL and HM can be simultaneously detected with LODs of 1.0 and 0.81 pg/mL, respectively. Furthermore, the recovery rates in urine samples ranged from 83 to 116% (relative standard deviation, RSD ≤ 6.4%) for CL and from 82 to 103% (RSD ≤ 5.1%) for HM, further confirming the reliability of the SERS-based immunoassay for practical applications.

ACS SensorsVol. 9(10)
Tianjin University of Science and Technology (CN), Nankai University (CN), Tianjin First Center Hospital (CN), Tianjin Medical University (CN)
National Natural Science Foundation of China, Tianjin Science and Technology Program
Zero hunger
Openalex Percentile: Top 10%
Pharmacological Effects and Assays
2.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.