Development and Validation of RoboCap, a Robotic Capillary Platform to Automate Capillary Electrophoresis Mass Spectrometry En Route to High-Throughput Single-Cell Proteomics

Current developments in single-cell mass spectrometry (MS) aim to deepen proteome coverage while enhancing analytical speed to study entire cell populations, one cell at a time. Custom-built microanalytical capillary electrophoresis (μCE) played a critical role in the foundation of discovery single-cell MS proteomics. However, requirements for manual operation, substantial expertise, and low measurement throughput have so far hindered μCE-based single-cell studies on large numbers of cells. Here, we design and construct a robotic capillary (RoboCap) platform that grants single-cell CE-MS with automation for proteomes limited to less than ∼100 nL. RoboCap remotely controls precision actuators to translate the sample to the fused silica separation capillary, using vials in this work. The platform is hermetically enclosed and actively pressurized to inject ∼1-250 nL of the sample into a CE separation capillary, with errors below ∼5% relative standard deviation (RSD). The platform and supporting equipment were operated and monitored remotely on a custom-written Virtual Instrument (LabView). Detection performance was validated empirically on ∼5-250 nL portions of the HeLa proteome digest using a trapped ion mobility mass spectrometer (timsTOF PRO). RoboCap improved CE-ESI sample utilization to ∼20% from ∼3% on the manual μCE, the closest reference technology. Proof-of-principle experiments found proteome identification and quantification to robustly return ∼1,800 proteins (∼13% RSD) from ∼20 ng of the HeLa proteome digest on this earlier-generation detector. RoboCap automates CE-MS for limited sample amounts, paving the way to electrophoresis-based high-throughput single-cell proteomics.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-09
DOI
https://doi.org/10.1021/acs.analchem.4c04353
Citations
14
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
2.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of RoboCap, a Robotic Capillary Platform to Automate Capillary Electrophoresis Mass Spectrometry En Route to High-Throughput Single-Cell Proteomics

Péter Nemes, Dashuang Jia
14 citations
Analytical Chemistry
Biosensors and Analytical Detection
2.58
article

Development and Validation of RoboCap, a Robotic Capillary Platform to Automate Capillary Electrophoresis Mass Spectrometry En Route to High-Throughput Single-Cell Proteomics

Péter Nemes, Dashuang Jia
article en
14 citations

Abstract

Current developments in single-cell mass spectrometry (MS) aim to deepen proteome coverage while enhancing analytical speed to study entire cell populations, one cell at a time. Custom-built microanalytical capillary electrophoresis (μCE) played a critical role in the foundation of discovery single-cell MS proteomics. However, requirements for manual operation, substantial expertise, and low measurement throughput have so far hindered μCE-based single-cell studies on large numbers of cells. Here, we design and construct a robotic capillary (RoboCap) platform that grants single-cell CE-MS with automation for proteomes limited to less than ∼100 nL. RoboCap remotely controls precision actuators to translate the sample to the fused silica separation capillary, using vials in this work. The platform is hermetically enclosed and actively pressurized to inject ∼1-250 nL of the sample into a CE separation capillary, with errors below ∼5% relative standard deviation (RSD). The platform and supporting equipment were operated and monitored remotely on a custom-written Virtual Instrument (LabView). Detection performance was validated empirically on ∼5-250 nL portions of the HeLa proteome digest using a trapped ion mobility mass spectrometer (timsTOF PRO). RoboCap improved CE-ESI sample utilization to ∼20% from ∼3% on the manual μCE, the closest reference technology. Proof-of-principle experiments found proteome identification and quantification to robustly return ∼1,800 proteins (∼13% RSD) from ∼20 ng of the HeLa proteome digest on this earlier-generation detector. RoboCap automates CE-MS for limited sample amounts, paving the way to electrophoresis-based high-throughput single-cell proteomics.

Analytical ChemistryVol. 96(42)
University of Maryland, College Park (US)
Arnold and Mabel Beckman Foundation, National Institutes of Health, A. James Clark School of Engineering, National Institute on Aging
Openalex Percentile: Top 10%
Biosensors and Analytical Detection
2.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.