Quantitative determination by UHPLC-MS/MS of 18 common drugs of abuse and metabolites, including THC and OH-THC, in volumetric dried blood spots: a sustainable method with minimally invasive sampling

The increased use of drugs of abuse urges forensic toxicologists to create quick, simple, minimally invasive sampling techniques for biological fluids combined with analytical methods assuring accurate results. To this purpose, a method was developed aimed at quantifying 18 drugs of abuse and metabolites in DBS. Validation of the method was conducted by spiking blank whole blood with the analytes on Capitainer® B cards. The extracts were analyzed by a targeted UHPLC-MS/MS method. Linear calibration was achieved in the range of 1-100 ng/mL for: amphetamine, MDA, MDMA, methamphetamine, cocaine, codeine, benzoylecgonine, cocaethylene, morphine, 6-MAM, buprenorphine, methadone, EDDP, ketamine, norbuprenorphine norketamine, THC, and OH-THC. Experimental LOD was found at 0.5 ng/mL for all analytes except for norbuprenorphine, THC and THC-OH which yielded a LOD of 1 ng/mL. Intra- and inter-day accuracy was satisfactory with bias% resulting within 5%. Evaluation of intra- and inter-day precision yielded CV% values within 20%, for all compounds except EDDP. Average extraction recovery calculated at low (2 ng/mL) and high (75 ng/mL) concentration levels was 63% while average matrix effect determined at the same levels was found to be within 85% - 115% for all analytes except from codeine (70%) and MDMA (131%). The method was applied to authentic blood samples spotted onto the DBS card and the minimum value detected was 1.3 ng/mL. HPLC-MS/MS proved capable to identify all the targeted analytes at low concentrations in the small blood volumes obtainable from DBS cards, which in turn confirmed to be effective and sustainable micro-sampling devices.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography B
Published
2024-10-01
DOI
https://doi.org/10.1016/j.jchromb.2024.124337
Citations
8
Primary Topic
Biosimilars and Bioanalytical Methods
Type
article
Field-Weighted Citation Impact
1.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative determination by UHPLC-MS/MS of 18 common drugs of abuse and metabolites, including THC and OH-THC, in volumetric dried blood spots: a sustainable method with minimally invasive sampling

Alberto Salomone, Christina Ververi, Marco Vincenti, Marta Massano et al.
8 citations
Journal of Chromatography B
Biosimilars and Bioanalytical Methods
1.92
article

Quantitative determination by UHPLC-MS/MS of 18 common drugs of abuse and metabolites, including THC and OH-THC, in volumetric dried blood spots: a sustainable method with minimally invasive sampling

Alberto Salomone, Christina Ververi, Marco Vincenti, Marta Massano, Claudia Gentile
article en
8 citations

Abstract

The increased use of drugs of abuse urges forensic toxicologists to create quick, simple, minimally invasive sampling techniques for biological fluids combined with analytical methods assuring accurate results. To this purpose, a method was developed aimed at quantifying 18 drugs of abuse and metabolites in DBS. Validation of the method was conducted by spiking blank whole blood with the analytes on Capitainer® B cards. The extracts were analyzed by a targeted UHPLC-MS/MS method. Linear calibration was achieved in the range of 1-100 ng/mL for: amphetamine, MDA, MDMA, methamphetamine, cocaine, codeine, benzoylecgonine, cocaethylene, morphine, 6-MAM, buprenorphine, methadone, EDDP, ketamine, norbuprenorphine norketamine, THC, and OH-THC. Experimental LOD was found at 0.5 ng/mL for all analytes except for norbuprenorphine, THC and THC-OH which yielded a LOD of 1 ng/mL. Intra- and inter-day accuracy was satisfactory with bias% resulting within 5%. Evaluation of intra- and inter-day precision yielded CV% values within 20%, for all compounds except EDDP. Average extraction recovery calculated at low (2 ng/mL) and high (75 ng/mL) concentration levels was 63% while average matrix effect determined at the same levels was found to be within 85% - 115% for all analytes except from codeine (70%) and MDMA (131%). The method was applied to authentic blood samples spotted onto the DBS card and the minimum value detected was 1.3 ng/mL. HPLC-MS/MS proved capable to identify all the targeted analytes at low concentrations in the small blood volumes obtainable from DBS cards, which in turn confirmed to be effective and sustainable micro-sampling devices.

Journal of Chromatography BVol. 1247
Centro Ricerche FIAT (IT), University of Turin (IT)
Openalex Percentile: Top 14%
Biosimilars and Bioanalytical Methods
1.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.