Design and implementation of a binocular stereo vision-based three-dimensional distance measurement method for situs anterior flexion

Objective: To design a stereoscopic ranging method for anterior flexion ranging using binocular stereo vision technology, and to verify its accuracy. Methods: A binocular camera was used to acquire the test images of the subjects, and OpenPose, an open source framework for human posture recognition, was used to intelligently detect the key points of the hands and reconstruct the 3D coordinates of the key points to complete the distance measurement. Results: A total of 240 sets of binocular images of seated forward bending were collected, and the maximum value was 2.1 mm, the minimum error was 0.1 mm, the average error was within 0.5 mm, and the standard deviation was 0.29. Conclusion: The accuracy of seated forward bending measurement was improved, and it can be applied to the measurement of seated forward bending in school physical fitness test.

Authors

Institutions

Publication Details

Published
2024-10-09
DOI
https://doi.org/10.1117/12.3045264
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and implementation of a binocular stereo vision-based three-dimensional distance measurement method for situs anterior flexion

Cheng Jiang, Kexin Qi, Jiaqi Sun, Chuanfan Xu et al.
Spine and Intervertebral Disc Pathology
article

Design and implementation of a binocular stereo vision-based three-dimensional distance measurement method for situs anterior flexion

Cheng Jiang, Kexin Qi, Jiaqi Sun, Chuanfan Xu, Xuanshang Jin
article en

Abstract

Objective: To design a stereoscopic ranging method for anterior flexion ranging using binocular stereo vision technology, and to verify its accuracy. Methods: A binocular camera was used to acquire the test images of the subjects, and OpenPose, an open source framework for human posture recognition, was used to intelligently detect the key points of the hands and reconstruct the 3D coordinates of the key points to complete the distance measurement. Results: A total of 240 sets of binocular images of seated forward bending were collected, and the maximum value was 2.1 mm, the minimum error was 0.1 mm, the average error was within 0.5 mm, and the standard deviation was 0.29. Conclusion: The accuracy of seated forward bending measurement was improved, and it can be applied to the measurement of seated forward bending in school physical fitness test.

Yanbian University (CN), Dalian University of Technology (CN)
Openalex Percentile: Top 72%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and implementation of a binocular stereo vision-based three-dimensional distance measurement method for situs anterior flexion — Cheng Jiang, Kexin Qi, et al. · (2024) | TGRS Research Map | TGRS