Protein-metal interactions due to fretting corrosion at the taper junction of hip implants: An in vitro investigation using Raman spectroscopy
Modular hip implants are a clinically successful and widely used treatment for patients with arthritis. Despite ongoing retrieval studies the understanding of the fundamental physico-chemical mechanisms of friction and wear within the head-taper interface is still limited. Here, we Raman-spectroscopically analyze structural features of the biotribological material which is formed within the taper joint between Ti6Al4V and low-carbon cobalt alloy or high-nitrogen steel surfaces in in vitro gross-slip fretting corrosion tests with bovine calf serum. As a function of the fretting duration, we investigate short and long aliphatic chains and their adsorption behavior on the cobalt- and steel-type surfaces. Using the intensity and frequency shifts of the amide I and III Raman bands, we furthermore identify progressive protein folding and unfolding including the secondary structures of α-helix, β-sheet, and random-coil configuration as well as the formation of proteinaceous clusters depending on the hydrophilicity of the metallic surfaces. We additionally find a mixture of chromates and iron oxides with tryptophan and tyrosine at the worn cobalt alloy and high-nitrogen steel surfaces, respectively. Also, for long fretting duration, sp<sup>2</sup> hybridized amorphous carbon is formed due to fretting-induced cleavage of proteins. STATEMENT OF SIGNIFICANCE: Despite efforts enhancing the biomedical tribology of hip implants, the impact of the organic environment on friction and wear at the femoral head-stem taper interface is limitedly understood. Using Raman spectroscopy we resolve structural changes within the biotribological material agglomerated at biomedical-grade metal alloys due to metal-organic interactions during in vitro fretting corrosion tests. Adsorption of short and long aliphatic chains, progressive protein (un)folding and proteinaceous cluster formation depend to a distinguishable extent on the fretting duration and type of alloy. Chromates and iron oxides are mixed with tryptophan and tyrosine, and amorphous carbon is formed resulting from a fretting-induced cleavage of serum proteins. Such information spectroscopically gleaned from biotribological material are vital to improve the design and performance of taper junctions.
Authors
- J. Debus (ORCID: https://orcid.org/0000-0002-8678-4402)
- Christian Beckmann (ORCID: https://orcid.org/0000-0002-5866-370X)
- Adrian Wittrock
- Saskia Heermant (ORCID: https://orcid.org/0000-0001-8528-9664)
- Markus A. Wimmer (ORCID: https://orcid.org/0000-0001-6169-3873)
- Alfons Fischer (ORCID: https://orcid.org/0000-0003-0407-2813)
- Marc Aßmann (ORCID: https://orcid.org/0000-0003-4953-1286)
Institutions
- Rush University Medical Center (US)
- TU Dortmund University (DE)
- Düsseldorf University Hospital (DE)
- Max-Planck-Institut für Nachhaltige Materialien (DE)
- Heinrich Heine University Düsseldorf (DE)
Publication Details
- Journal
- Acta Biomaterialia
- Published
- 2024-10-09
- DOI
- https://doi.org/10.1016/j.actbio.2024.10.006
- Citations
- 5
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 2.86