A Quantitative Analysis of Harmonic Effects on the Accuracy of Single-Phase kWh Meters in PT. PLN (Persero) ULP Kuta

The accurate measurement of electrical energy transactions using kWh meters is crucial to prevent losses for both consumers and utilities. However, the growing prevalence of nonlinear loads can introduce harmonics into the power system, potentially affecting the accuracy of kWh meter readings. This study aimed to investigate the impact of harmonics on the measurement accuracy of analog and electromechanical kWh meters. The results demonstrate that as the percentage of Total Harmonic Distortion (%THD) increases, due to the increased use of nonlinear loads, the measurement accuracy of both types of kWh meters decreases, potentially leading to financial losses for both consumers and the utility company. Based on the study, Simulation results demonstrate this impact, with analog and electromechanical kWh meters showing significantly different billing outcomes under resistive and capacitive loads. For example, a purely resistive 300-watt load resulted in a bill of Rp. 327,870 for the analog meter and Rp. 319,343 for the electromechanical meter. In contrast, a 300-watt capacitive load resulted in bills of Rp. 84,497 and Rp. 83,707, respectively.

Authors

Institutions

Publication Details

Journal
FIDELITY Jurnal Teknik Elektro
Published
2024-09-30
DOI
https://doi.org/10.52005/fidelity.v6i3.255
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Quantitative Analysis of Harmonic Effects on the Accuracy of Single-Phase kWh Meters in PT. PLN (Persero) ULP Kuta

Dewa Ayu Putu Adhiya Garini Putri, I Wayan Sutama, Muhamma Yusrul Falah
FIDELITY Jurnal Teknik Elektro
Engineering and Technology Innovations
article

A Quantitative Analysis of Harmonic Effects on the Accuracy of Single-Phase kWh Meters in PT. PLN (Persero) ULP Kuta

Dewa Ayu Putu Adhiya Garini Putri, I Wayan Sutama, Muhamma Yusrul Falah
article en

Abstract

The accurate measurement of electrical energy transactions using kWh meters is crucial to prevent losses for both consumers and utilities. However, the growing prevalence of nonlinear loads can introduce harmonics into the power system, potentially affecting the accuracy of kWh meter readings. This study aimed to investigate the impact of harmonics on the measurement accuracy of analog and electromechanical kWh meters. The results demonstrate that as the percentage of Total Harmonic Distortion (%THD) increases, due to the increased use of nonlinear loads, the measurement accuracy of both types of kWh meters decreases, potentially leading to financial losses for both consumers and the utility company. Based on the study, Simulation results demonstrate this impact, with analog and electromechanical kWh meters showing significantly different billing outcomes under resistive and capacitive loads. For example, a purely resistive 300-watt load resulted in a bill of Rp. 327,870 for the analog meter and Rp. 319,343 for the electromechanical meter. In contrast, a 300-watt capacitive load resulted in bills of Rp. 84,497 and Rp. 83,707, respectively.

FIDELITY Jurnal Teknik ElektroVol. 6(3)
University of National Education (ID)
Affordable and clean energy
Openalex Percentile: Top 85%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.