Comparative assessment of nucleated red blood cells using a fully automated hematology analyzer versus slide examination.

Objective: To determine the sensitivity and specificity of fully automated hematology analyzer for nucleated red blood cells (NRBCs) keeping microscopic slide examination as gold standard. Study Design: Cross-sectional study. Setting: Department of Hematology, RMI Hospital, Peshawar. Period: 1st December 2023 to 29th Feb 2024. Methods: A total of 160 blood samples referred for assessment to the hematological department for the suspected abnormal NRBCs were included in the study through consecutive sampling. Fresh Blood samples were analyzed using fully automated hematology analyzer. Manual counting of the NRBCs of the same samples was done using manual blood smear slide examination. Findings of the automated nucleated red blood cell counting methods were statistically analyzed keeping microscopic slide examination as gold standard. Sensitivity, specificity, accuracy and negative and positive predictive values were calculated for diagnosis of NRBC (count >0.02 × 109/L). Clinical sensitivity of the test was determined by Receiver Operating Test (ROC). Results: The Mean±SD of patient’s age in this study was 46.78±14.89 years with an age range of 0.5 to 67 years. The male gender was 53.75% while female gender was 46.25%. Fully automated hematology analyzer detected 30 (18.75%) samples while slide examination detected 31 (19.37%) samples with NRBC count >0.02 × 109/L. Fully automated hematology analyzer has shown sensitivity of 93.55 %, specificity 99.23% and diagnostic accuracy by 98.13%. PPV was 96.67% and NPV was 98.46 (p < 0.000) for the diagnosis of NRBC. The cutoff value of 0.0175 × 109/L (20/µL) offered the best balance between sensitivity and specificity based on ROC curve. Conclusion: Association is present for the NRBC count among the fully automated hematology analyzer and microscopic slide examination.

Authors

Publication Details

Journal
The Professional Medical Journal
Published
2024-09-02
DOI
https://doi.org/10.29309/tpmj/2024.31.09.8195
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative assessment of nucleated red blood cells using a fully automated hematology analyzer versus slide examination.

Sobia Bashir, Ayesha Ishtiaq, Humaira Taj Niazi, Maryam Zahra et al.
The Professional Medical Journal
Digital Imaging for Blood Diseases
article

Comparative assessment of nucleated red blood cells using a fully automated hematology analyzer versus slide examination.

Sobia Bashir, Ayesha Ishtiaq, Humaira Taj Niazi, Maryam Zahra, Shahtaj Khan
article en

Abstract

Objective: To determine the sensitivity and specificity of fully automated hematology analyzer for nucleated red blood cells (NRBCs) keeping microscopic slide examination as gold standard. Study Design: Cross-sectional study. Setting: Department of Hematology, RMI Hospital, Peshawar. Period: 1st December 2023 to 29th Feb 2024. Methods: A total of 160 blood samples referred for assessment to the hematological department for the suspected abnormal NRBCs were included in the study through consecutive sampling. Fresh Blood samples were analyzed using fully automated hematology analyzer. Manual counting of the NRBCs of the same samples was done using manual blood smear slide examination. Findings of the automated nucleated red blood cell counting methods were statistically analyzed keeping microscopic slide examination as gold standard. Sensitivity, specificity, accuracy and negative and positive predictive values were calculated for diagnosis of NRBC (count >0.02 × 109/L). Clinical sensitivity of the test was determined by Receiver Operating Test (ROC). Results: The Mean±SD of patient’s age in this study was 46.78±14.89 years with an age range of 0.5 to 67 years. The male gender was 53.75% while female gender was 46.25%. Fully automated hematology analyzer detected 30 (18.75%) samples while slide examination detected 31 (19.37%) samples with NRBC count >0.02 × 109/L. Fully automated hematology analyzer has shown sensitivity of 93.55 %, specificity 99.23% and diagnostic accuracy by 98.13%. PPV was 96.67% and NPV was 98.46 (p < 0.000) for the diagnosis of NRBC. The cutoff value of 0.0175 × 109/L (20/µL) offered the best balance between sensitivity and specificity based on ROC curve. Conclusion: Association is present for the NRBC count among the fully automated hematology analyzer and microscopic slide examination.

The Professional Medical JournalVol. 31(09)
Openalex Percentile: Top 83%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.