Computed tomography employing sensing of high energy particle current

<i>Objective</i>. We demonstrate High Energy Current Computed Tomography (HEC-CT) employing megavoltage linac x-rays.<i>Approach</i>. Using deterministic radiation transport we simulate two-parameter HEC-CT projections and using inverse Fourier transform we reconstruct two distinct material parameters for water phantoms with ICRP tissue inserts and materials of different atomic number Z. The HEC-CT projections are obtained by beam scanning and rotating the object.<i>Main Results</i>. The first HEC-CT material parameter is alike the standard attenuation coefficient with dependence on atomic number and material density similar to the Hounsfield Units. The second material parameter has opposite trends and does not find any analogy in the standard CT framework.<i>Significance</i>. New CT method has been invented for medical imaging or non-destructive testing. The key feature of the technique is a two-value CT reconstruction based on particle current instead of transmitted dose.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2024-10-08
DOI
https://doi.org/10.1088/2057-1976/ad844d
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computed tomography employing sensing of high energy particle current

Piotr Zygmanski, Davide Brivio, Wolfgang Hoegele
Biomedical Physics & Engineering Express
Advanced X-ray and CT Imaging
article

Computed tomography employing sensing of high energy particle current

Piotr Zygmanski, Davide Brivio, Wolfgang Hoegele
article en

Abstract

<i>Objective</i>. We demonstrate High Energy Current Computed Tomography (HEC-CT) employing megavoltage linac x-rays.<i>Approach</i>. Using deterministic radiation transport we simulate two-parameter HEC-CT projections and using inverse Fourier transform we reconstruct two distinct material parameters for water phantoms with ICRP tissue inserts and materials of different atomic number Z. The HEC-CT projections are obtained by beam scanning and rotating the object.<i>Main Results</i>. The first HEC-CT material parameter is alike the standard attenuation coefficient with dependence on atomic number and material density similar to the Hounsfield Units. The second material parameter has opposite trends and does not find any analogy in the standard CT framework.<i>Significance</i>. New CT method has been invented for medical imaging or non-destructive testing. The key feature of the technique is a two-value CT reconstruction based on particle current instead of transmitted dose.

Biomedical Physics & Engineering ExpressVol. 10(6)
Brigham and Women's Hospital (US), Munich University of Applied Sciences (DE)
Affordable and clean energy
Openalex Percentile: Top 84%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Computed tomography employing sensing of high energy particle current — Piotr Zygmanski, Davide Brivio, et al. · Biomedical Physics & Engineering Express (2024) | TGRS Research Map | TGRS