The dosimetric accuracy of a commercial model-based dose calculation algorithm in modeling a six-groove direction modulated brachytherapy tandem applicator

<i>Objective.</i>With advancements in high-dose rate brachytherapy, the clinical translation of intensity modulated brachytherapy (IMBT) innovations necessitates utilization of model-based dose calculation algorithms (MBDCA) for accurate and rapid dose calculations. This study uniquely benchmarks a commercial MBDCA, BrachyVision ACUROS<sup>TM</sup>(BVA), against Monte Carlo (MC) simulations, evaluating dose distributions for a novel IMBT applicator, termed as the<i>six-groove</i>Direction Modulated Brachytherapy (DMBT) tandem, expanding beyond previous focus on partially shielded vaginal cylinder applicators, through a novel methodology.<i>Approach.</i>The DMBT tandem applicator, made of a tungsten alloy with six evenly spaced grooves, was simulated using the GEANT4 MC code. Subsequently, two main scenarios were created using the BVA and reproduced by the MC simulations: '<i>Source at the Center of the Water Phantom (SACWP)</i>' and '<i>Source at the Middle of the Applicator (SAMA)</i>' for three cubical virtual water phantoms (20 cm)<sup>3</sup>, (30 cm)<sup>3</sup>, and (40 cm)<sup>3</sup>. A track length estimator was utilized for dose calculation and 2D/3D scoring were performed. The difference in isodose surfaces/lines (i.e. coverage) at each voxel,<i>ΔD</i><sub>Isodose Levels/Lines</sub>, was thus calculated for relevant normalization points (<i>r</i><sub>ref</sub>).<i>Results.</i>The coverage was comparable, based on 2D scoring, between the BVA and MC isodose surfaces/lines for the region of clinical relevance, (i.e. within 5 cm radius from the source) with<i>ΔD</i><sub>Isodose Lines</sub>(<i>r</i><sub>ref</sub>: 1 cm from the source) falling within 2% for the two scenarios for all phantom sizes. For the phantom (20 cm)<sup>3</sup>,<i>ΔD</i><sub>Isodose Levels</sub>(3D scoring) recorded the range [-3.0% +6.5%] ([-7.4% +7.3%]) for 95% of the voxels of the same scoring volume for the SACWP (SAMA) scenario.<i>Significance.</i>The results indicated that the BVA could render comparable coverage as compared to the MC simulations in the region of clinical relevance for different phantom sizes.<i>ΔD</i><sub>Isodose Lines</sub>may offer an advantageous metric for evaluation of MBDCAs in clinical setting.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-08
DOI
https://doi.org/10.1088/1361-6560/ad84b6
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The dosimetric accuracy of a commercial model-based dose calculation algorithm in modeling a six-groove direction modulated brachytherapy tandem applicator

Moeen Meftahi, William Y. Song
2 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
1.22
article

The dosimetric accuracy of a commercial model-based dose calculation algorithm in modeling a six-groove direction modulated brachytherapy tandem applicator

Moeen Meftahi, William Y. Song
article en
2 citations

Abstract

<i>Objective.</i>With advancements in high-dose rate brachytherapy, the clinical translation of intensity modulated brachytherapy (IMBT) innovations necessitates utilization of model-based dose calculation algorithms (MBDCA) for accurate and rapid dose calculations. This study uniquely benchmarks a commercial MBDCA, BrachyVision ACUROS<sup>TM</sup>(BVA), against Monte Carlo (MC) simulations, evaluating dose distributions for a novel IMBT applicator, termed as the<i>six-groove</i>Direction Modulated Brachytherapy (DMBT) tandem, expanding beyond previous focus on partially shielded vaginal cylinder applicators, through a novel methodology.<i>Approach.</i>The DMBT tandem applicator, made of a tungsten alloy with six evenly spaced grooves, was simulated using the GEANT4 MC code. Subsequently, two main scenarios were created using the BVA and reproduced by the MC simulations: '<i>Source at the Center of the Water Phantom (SACWP)</i>' and '<i>Source at the Middle of the Applicator (SAMA)</i>' for three cubical virtual water phantoms (20 cm)<sup>3</sup>, (30 cm)<sup>3</sup>, and (40 cm)<sup>3</sup>. A track length estimator was utilized for dose calculation and 2D/3D scoring were performed. The difference in isodose surfaces/lines (i.e. coverage) at each voxel,<i>ΔD</i><sub>Isodose Levels/Lines</sub>, was thus calculated for relevant normalization points (<i>r</i><sub>ref</sub>).<i>Results.</i>The coverage was comparable, based on 2D scoring, between the BVA and MC isodose surfaces/lines for the region of clinical relevance, (i.e. within 5 cm radius from the source) with<i>ΔD</i><sub>Isodose Lines</sub>(<i>r</i><sub>ref</sub>: 1 cm from the source) falling within 2% for the two scenarios for all phantom sizes. For the phantom (20 cm)<sup>3</sup>,<i>ΔD</i><sub>Isodose Levels</sub>(3D scoring) recorded the range [-3.0% +6.5%] ([-7.4% +7.3%]) for 95% of the voxels of the same scoring volume for the SACWP (SAMA) scenario.<i>Significance.</i>The results indicated that the BVA could render comparable coverage as compared to the MC simulations in the region of clinical relevance for different phantom sizes.<i>ΔD</i><sub>Isodose Lines</sub>may offer an advantageous metric for evaluation of MBDCAs in clinical setting.

Physics in Medicine and BiologyVol. 69(21)
Emory University (US), Virginia Commonwealth University (US)
Openalex Percentile: Top 21%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.