First test beam of the DMAPS-based proton tracker at the pMBRT facility at the Curie Institute

<i>Objective.</i>Proton radiotherapy's efficacy relies on an accurate relative stopping power (RSP) map of the patient to optimise the treatment plan and minimize uncertainties. Currently, a conversion of a Hounsfield Units map obtained by a common x-ray computed tomography (CT) is used to compute the RSP. This conversion is one of the main limiting factors for proton radiotherapy. To bypass this conversion a direct RSP map could be obtained by performing a proton CT (pCT). The focal point of this article is to present a proof of concept of the potential of fast pixel technologies for proton tracking at clinical facilities.<i>Approach.</i>A two-layer tracker based on the TJ-Monopix1, a depleted monolithic active pixel sensor (DMAPS) chip initially designed for the ATLAS, was tested at the proton minibeam radiotherapy beamline at the Curie Institute. The chips were subjected to 100 MeV protons passing through the single slit collimator (0.4×20mm<sup>2</sup>) with fluxes up to1.3×107p s<sup>-1</sup> cm<sup>-2</sup>. The performance of the proton tracker was evaluated with GEANT4 simulations.<i>Main results.</i>The beam profile and dispersion in air were characterized by an opening of 0.031 mm cm<sup>-1</sup>, and aσx=0.172mm at the position of the slit. The results of the proton tracking show how the TJ-Monopix1 chip can effectively track protons in a clinical environment, achieving a tracking purity close to 70%, and a position resolution below 0.5 mm; confirming the chip's ability to handle high proton fluxes with a competitive performance.<i>Significance.</i>This work suggests that DMAPS technologies can be a cost-effective alternative for proton imaging. Additionally, the study identifies areas where further optimization of chip design is required to fully leverage these technologies for clinical ion imaging applications.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-08
DOI
https://doi.org/10.1088/1361-6560/ad84b3
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First test beam of the DMAPS-based proton tracker at the pMBRT facility at the Curie Institute

T. Hemperek, Ludovic De Marzi, L. Gonella, T. Hirono et al.
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

First test beam of the DMAPS-based proton tracker at the pMBRT facility at the Curie Institute

T. Hemperek, Ludovic De Marzi, L. Gonella, T. Hirono, Κωνσταντίνος Μουστάκας, M. Gonzalez, Annalisa Patriarca, Tony Price
article en

Abstract

<i>Objective.</i>Proton radiotherapy's efficacy relies on an accurate relative stopping power (RSP) map of the patient to optimise the treatment plan and minimize uncertainties. Currently, a conversion of a Hounsfield Units map obtained by a common x-ray computed tomography (CT) is used to compute the RSP. This conversion is one of the main limiting factors for proton radiotherapy. To bypass this conversion a direct RSP map could be obtained by performing a proton CT (pCT). The focal point of this article is to present a proof of concept of the potential of fast pixel technologies for proton tracking at clinical facilities.<i>Approach.</i>A two-layer tracker based on the TJ-Monopix1, a depleted monolithic active pixel sensor (DMAPS) chip initially designed for the ATLAS, was tested at the proton minibeam radiotherapy beamline at the Curie Institute. The chips were subjected to 100 MeV protons passing through the single slit collimator (0.4×20mm<sup>2</sup>) with fluxes up to1.3×107p s<sup>-1</sup> cm<sup>-2</sup>. The performance of the proton tracker was evaluated with GEANT4 simulations.<i>Main results.</i>The beam profile and dispersion in air were characterized by an opening of 0.031 mm cm<sup>-1</sup>, and aσx=0.172mm at the position of the slit. The results of the proton tracking show how the TJ-Monopix1 chip can effectively track protons in a clinical environment, achieving a tracking purity close to 70%, and a position resolution below 0.5 mm; confirming the chip's ability to handle high proton fluxes with a competitive performance.<i>Significance.</i>This work suggests that DMAPS technologies can be a cost-effective alternative for proton imaging. Additionally, the study identifies areas where further optimization of chip design is required to fully leverage these technologies for clinical ion imaging applications.

Physics in Medicine and BiologyVol. 69(21)
Karlsruhe Institute of Technology (DE), University of Bonn (DE), Paul Scherrer Institute (CH), Tris Pharma (United States) (US), European Organization for Nuclear Research (CH), University of Birmingham (GB), Institut Curie (FR), Institut des Hautes Études Scientifiques (FR)
Science and Technology Facilities Council
Openalex Percentile: Top 68%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.