PICASSO: a universal brain phantom for positron emission tomography based on the activity painting technique

<i>Objective</i>. This study presents a universal phantom for positron emission tomography (PET) that allows arbitrary static and dynamic activity distributions of various complexities to be generated using a single PET acquisition.<i>Approach</i>. We collected a high-statistics dataset (with a total of 22.4 × 10<sup>9</sup>prompt coincidences and an event density of 2.75 × 10<sup>6</sup>events mm<sup>-3</sup>) by raster-scanning a single plane with a<sup>22</sup>Na point source mounted on a robotic arm in the field-of-view of the uEXPLORER PET/CT scanner. The source position was determined from the reconstructed dynamic frames. Uniquely, true coincidences were separated from scattered and random events based on the distance between their line-of-response and the known source location. Finally, we randomly sampled the dataset to generate the desired activity distributions modeling several different phantoms.<i>Main results</i>. Overall, the target and the reconstructed phantom images had good agreement. The analysis of a simple geometric distribution showed high quantitative accuracy of the phantom, with mean error of <-3.0% relative to the ground truth for activity concentrations ranging from 5.3 to 47.7 kBq ml<sup>-1</sup>. The model of a high-resolution<sup>18</sup>F-fluorodeoxyglucose distribution in the brain illustrates the usefulness of the technique in simulating realistic static neuroimaging studies. A dynamic<sup>18</sup>F-florbetaben study was modeled based on the time-activity curves of a human study and a segmented brain phantom with no coincidences repeating between frames. For all time points, the mean voxel-wise errors ranged from -4.4% to -0.7% in grey matter and from -3.9% to +2.8% in white matter.<i>Significance</i>. The proposed phantom technique is highly flexible and allows modeling of static and dynamic brain PET studies with high quantitative accuracy. It overcomes several key limitations of the existing phantoms and has many promising applications for the purposes of image reconstruction, data correction methods, and system performance evaluation, particularly for new high-performance dedicated brain PET scanners.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-08
DOI
https://doi.org/10.1088/1361-6560/ad84b5
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PICASSO: a universal brain phantom for positron emission tomography based on the activity painting technique

Jinyi Qi, Simon R. Cherry, Bangyan Huang, Ekaterina Shanina et al.
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

PICASSO: a universal brain phantom for positron emission tomography based on the activity painting technique

Jinyi Qi, Simon R. Cherry, Bangyan Huang, Ekaterina Shanina, Tiantian Li, Benjamin A. Spencer
article en

Abstract

<i>Objective</i>. This study presents a universal phantom for positron emission tomography (PET) that allows arbitrary static and dynamic activity distributions of various complexities to be generated using a single PET acquisition.<i>Approach</i>. We collected a high-statistics dataset (with a total of 22.4 × 10<sup>9</sup>prompt coincidences and an event density of 2.75 × 10<sup>6</sup>events mm<sup>-3</sup>) by raster-scanning a single plane with a<sup>22</sup>Na point source mounted on a robotic arm in the field-of-view of the uEXPLORER PET/CT scanner. The source position was determined from the reconstructed dynamic frames. Uniquely, true coincidences were separated from scattered and random events based on the distance between their line-of-response and the known source location. Finally, we randomly sampled the dataset to generate the desired activity distributions modeling several different phantoms.<i>Main results</i>. Overall, the target and the reconstructed phantom images had good agreement. The analysis of a simple geometric distribution showed high quantitative accuracy of the phantom, with mean error of <-3.0% relative to the ground truth for activity concentrations ranging from 5.3 to 47.7 kBq ml<sup>-1</sup>. The model of a high-resolution<sup>18</sup>F-fluorodeoxyglucose distribution in the brain illustrates the usefulness of the technique in simulating realistic static neuroimaging studies. A dynamic<sup>18</sup>F-florbetaben study was modeled based on the time-activity curves of a human study and a segmented brain phantom with no coincidences repeating between frames. For all time points, the mean voxel-wise errors ranged from -4.4% to -0.7% in grey matter and from -3.9% to +2.8% in white matter.<i>Significance</i>. The proposed phantom technique is highly flexible and allows modeling of static and dynamic brain PET studies with high quantitative accuracy. It overcomes several key limitations of the existing phantoms and has many promising applications for the purposes of image reconstruction, data correction methods, and system performance evaluation, particularly for new high-performance dedicated brain PET scanners.

Physics in Medicine and BiologyVol. 69(21)
United Imaging Healthcare (China) (CN), University of California, Davis (US)
National Institutes of Health, University of California, Davis
Openalex Percentile: Top 71%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.