Analysis of Optimal HVDC Back-to-Back Placement Based on Composite System Reliability

HVDC is a promising interconnection solution for connecting asynchronous systems and ensuring power control. In Indonesia, a remote industrial system in Sumatra is experiencing load growth and has the option to draw power from the Sumatra system. However, due to frequency differences, the use of HVDC is crucial. The Generation Expansion Planning has proposed six converters but not their interconnection points. This study will determine the most reliable interconnection locations. The chosen converters are modular multilevel converters (MMCs) with high modularity. The converter reliability modeling considers voltage levels, the number of modules, and redundancy strategies. This modeling is then implemented at the power system level to obtain the best placement at the available high-voltage (HV) substation options. Determining the best placement is based on the optimal reliability index. The optimal placement also includes the option to convert from HV to medium-voltage (MV) interconnection. MV interconnection offers higher flexibility but tends to be more expensive. The availability for HV converters is 99.69%, while for MV converters, it is slightly higher, at 99.81%. Additionally, converting from HV to MV reduces the SAIFI (system average interruption frequency index) from 0.2668 to 0.2284 occurrences per year, lowering the interruption cost from 7.804 million USD to 5.737 million USD per year. The sensitivity of interruption, investment, and maintenance costs shows that converting at least one HV converter to MV remains economical. In this case study, the optimal converter placement includes Area VI–2, recommended for conversion from HV to a more distributed MV configuration, improving reliability and economic efficiency.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-10-08
DOI
https://doi.org/10.3390/en17195008
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Optimal HVDC Back-to-Back Placement Based on Composite System Reliability

Nanang Hariyanto, Kevin Marojahan Banjar-Nahor, Hendry Timotiyas Paradongan, Niko Bernardus Simamora
Energies
High-Voltage Power Transmission Systems
article

Analysis of Optimal HVDC Back-to-Back Placement Based on Composite System Reliability

Nanang Hariyanto, Kevin Marojahan Banjar-Nahor, Hendry Timotiyas Paradongan, Niko Bernardus Simamora
article en

Abstract

HVDC is a promising interconnection solution for connecting asynchronous systems and ensuring power control. In Indonesia, a remote industrial system in Sumatra is experiencing load growth and has the option to draw power from the Sumatra system. However, due to frequency differences, the use of HVDC is crucial. The Generation Expansion Planning has proposed six converters but not their interconnection points. This study will determine the most reliable interconnection locations. The chosen converters are modular multilevel converters (MMCs) with high modularity. The converter reliability modeling considers voltage levels, the number of modules, and redundancy strategies. This modeling is then implemented at the power system level to obtain the best placement at the available high-voltage (HV) substation options. Determining the best placement is based on the optimal reliability index. The optimal placement also includes the option to convert from HV to medium-voltage (MV) interconnection. MV interconnection offers higher flexibility but tends to be more expensive. The availability for HV converters is 99.69%, while for MV converters, it is slightly higher, at 99.81%. Additionally, converting from HV to MV reduces the SAIFI (system average interruption frequency index) from 0.2668 to 0.2284 occurrences per year, lowering the interruption cost from 7.804 million USD to 5.737 million USD per year. The sensitivity of interruption, investment, and maintenance costs shows that converting at least one HV converter to MV remains economical. In this case study, the optimal converter placement includes Area VI–2, recommended for conversion from HV to a more distributed MV configuration, improving reliability and economic efficiency.

EnergiesVol. 17(19)
Bandung Institute of Technology (ID)
Udenrigsministeriet
Industry, innovation and infrastructure
Openalex Percentile: Top 85%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.