Performance-Dryout Limits of Oscillating Heat Pipes: A Comprehensive Theoretical and Experimental Determination

The performance limits of oscillating heat pipes (OHPs) have been the subject of research in recent years in order to understand their limitations and allow their broad application in the aerospace field. The present work describes the experimental determination of the performance dryout limits for an additively manufactured OHP geometry filled with R-134a and R-123, as well as the performance limits theoretical predictions using a recently developed analytical approach. Thermal experiments were carried out using a constant-temperature cold-plate approach at three cold plate temperatures, allowing the OHP device to reach steady state for each power step. Results show good agreement for the performance limits predictions with experimental data for both working fluids R-134a and R-123, opening the way for the analytical framework to be used in the design and development of OHPs.

Authors

Institutions

Publication Details

Journal
Journal of Thermophysics and Heat Transfer
Published
2024-10-08
DOI
https://doi.org/10.2514/1.t6955
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance-Dryout Limits of Oscillating Heat Pipes: A Comprehensive Theoretical and Experimental Determination

J. A. Muñoz, Benjamin Furst, Spencer Miesner, Kieran Wolk et al.
1 links
Journal of Thermophysics and Heat Transfer
Heat Transfer and Boiling Studies
article

Performance-Dryout Limits of Oscillating Heat Pipes: A Comprehensive Theoretical and Experimental Determination

J. A. Muñoz, Benjamin Furst, Spencer Miesner, Kieran Wolk, Scott Roberts, Arturo Martínez Rodríguez, Cesar Diaz-Caraveo, Vinod Kumar, M. Montemayor, Takuro Daimaru
article en

Abstract

The performance limits of oscillating heat pipes (OHPs) have been the subject of research in recent years in order to understand their limitations and allow their broad application in the aerospace field. The present work describes the experimental determination of the performance dryout limits for an additively manufactured OHP geometry filled with R-134a and R-123, as well as the performance limits theoretical predictions using a recently developed analytical approach. Thermal experiments were carried out using a constant-temperature cold-plate approach at three cold plate temperatures, allowing the OHP device to reach steady state for each power step. Results show good agreement for the performance limits predictions with experimental data for both working fluids R-134a and R-123, opening the way for the analytical framework to be used in the design and development of OHPs.

Journal of Thermophysics and Heat TransferVol. 39(2)
California Institute of Technology (US), Jet Propulsion Laboratory (US), University of California, Los Angeles (US), The University of Texas at El Paso (US), California State University Los Angeles (US)
Advanced Research Projects Agency - Energy, Jet Propulsion Laboratory, Air Force Office of Scientific Research
Affordable and clean energy
Openalex Percentile: Top 83%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.