In Vitro Investigation Using a New Biomechanical Force–Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers

(1) Background: After more than a decade since their first description, Inadvertent Tooth Movements (ITMs) remain an adverse effect of orthodontic retainers without a clear etiology. To further investigate the link between ITMs and the mechanical properties of different retainers, the response upon vertical loading was compared in three retainer types (two stainless steel and one nickel-titanium). The influence of different reference teeth was also considered. (2) Methods: Three retainers (R1, R2, R3) were tested in a newly developed biomechanical analysis system (FRANS). They were bonded to 3D-printed models of the lower anterior jaw and vertically displaced up to 0.3 mm. Developing forces and moments were recorded at the center of force. (3) Results: The vertical displacement caused vertical forces (Fz) and labiolingual moments (My) to arise. These were highest in the lateral incisors (up to 2.35 ± 0.59 N and 9.27 ± 5.86 Nmm for R1; 1.69 ± 1.06 N and 7.42 ± 2.65 Nmm for R2; 3.28 ± 1.73 N and 15.91 ± 9.71 Nmm for R3) for all analyzed retainers and with the R3 retainer for all analyzed reference teeth, while the lowest Fz and My values were recorded with the R1 retainer. (4) Conclusions: Displacements of 0.2 mm and larger provided forces and moments which could be sufficient to cause unwanted torque movements, such as ITMs, in all analyzed retainers. Clinicians must be mindful of these risks and perform post-treatment checkups on patients with retainers of all materials.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-10-08
DOI
https://doi.org/10.3390/ma17194916
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Investigation Using a New Biomechanical Force–Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers

Andrea Wichelhaus, Hisham Sabbagh, Matthias Mertmann, Linus Hötzel et al.
Materials
Orthodontics and Dentofacial Orthopedics
article

In Vitro Investigation Using a New Biomechanical Force–Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers

Andrea Wichelhaus, Hisham Sabbagh, Matthias Mertmann, Linus Hötzel, Francesca Thaden
article en

Abstract

(1) Background: After more than a decade since their first description, Inadvertent Tooth Movements (ITMs) remain an adverse effect of orthodontic retainers without a clear etiology. To further investigate the link between ITMs and the mechanical properties of different retainers, the response upon vertical loading was compared in three retainer types (two stainless steel and one nickel-titanium). The influence of different reference teeth was also considered. (2) Methods: Three retainers (R1, R2, R3) were tested in a newly developed biomechanical analysis system (FRANS). They were bonded to 3D-printed models of the lower anterior jaw and vertically displaced up to 0.3 mm. Developing forces and moments were recorded at the center of force. (3) Results: The vertical displacement caused vertical forces (Fz) and labiolingual moments (My) to arise. These were highest in the lateral incisors (up to 2.35 ± 0.59 N and 9.27 ± 5.86 Nmm for R1; 1.69 ± 1.06 N and 7.42 ± 2.65 Nmm for R2; 3.28 ± 1.73 N and 15.91 ± 9.71 Nmm for R3) for all analyzed retainers and with the R3 retainer for all analyzed reference teeth, while the lowest Fz and My values were recorded with the R1 retainer. (4) Conclusions: Displacements of 0.2 mm and larger provided forces and moments which could be sufficient to cause unwanted torque movements, such as ITMs, in all analyzed retainers. Clinicians must be mindful of these risks and perform post-treatment checkups on patients with retainers of all materials.

MaterialsVol. 17(19)
LMU Klinikum (DE), Ludwig-Maximilians-Universität München (DE)
Sustainable cities and communities
Openalex Percentile: Top 81%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Vitro Investigation Using a New Biomechanical Force–Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers — Andrea Wichelhaus, Hisham Sabbagh, et al. · Materials (2024) | TGRS Research Map | TGRS