Surface Engineering of Ti6Al4V: Impact of Rhenium–Carbon Coatings with Molybdenum Anchors on Biocompatibility and Corrosion Behavior

Titanium alloys, particularly Ti6Al4V, are widely used in biomedical applications due to their excellent mechanical properties and inherent biocompatibility. However, enhancing their surface characteristics, such as biocompatibility and corrosion resistance, remains a key challenge for their long-term use in medical implants. In this study, we investigate the effects of rhenium–carbon coatings deposited on Ti6Al4V substrates via magnetron sputtering, incorporating a molybdenum anchoring layer. X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS) analyses confirmed the formation of rhenium carbides, elemental rhenium, and rhenium oxides within the coatings. Despite these successful depositions, scanning electron microscopy (SEM) revealed significant delamination and poor adhesion of the coatings to the Ti6Al4V substrates. Corrosion resistance, evaluated through potentiodynamic polarization tests, showed an increase in corrosion current densities and more negative corrosion potentials, indicating a detrimental effect on the substrate’s corrosion resistance. Biocompatibility assessments using PK15 cells demonstrated a marked decrease in cell viability and metabolic activity, particularly in samples with higher surface roughness. These findings underscore the critical need for the optimization of surface preparation and deposition processes to improve both the adhesion and biocompatibility of rhenium–carbon coatings on Ti6Al4V substrates. Future research should aim to refine coating technique to enhance adhesion, explore the mechanisms of cytotoxicity related to surface roughness, and expand biocompatibility studies across different cell lines and biological environments.

Authors

Institutions

Publication Details

Journal
Metals
Published
2024-10-08
DOI
https://doi.org/10.3390/met14101144
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Engineering of Ti6Al4V: Impact of Rhenium–Carbon Coatings with Molybdenum Anchors on Biocompatibility and Corrosion Behavior

Adriana P. Corredor-Figueroa, Giovany Orozco-Hernández, Yaneth Pineda Triana, Willian Aperador et al.
Metals
Bone Tissue Engineering Materials
article

Surface Engineering of Ti6Al4V: Impact of Rhenium–Carbon Coatings with Molybdenum Anchors on Biocompatibility and Corrosion Behavior

Adriana P. Corredor-Figueroa, Giovany Orozco-Hernández, Yaneth Pineda Triana, Willian Aperador, Sara V. Mosquera-Diaz, Juliana V. Ramírez-Monroy
article en

Abstract

Titanium alloys, particularly Ti6Al4V, are widely used in biomedical applications due to their excellent mechanical properties and inherent biocompatibility. However, enhancing their surface characteristics, such as biocompatibility and corrosion resistance, remains a key challenge for their long-term use in medical implants. In this study, we investigate the effects of rhenium–carbon coatings deposited on Ti6Al4V substrates via magnetron sputtering, incorporating a molybdenum anchoring layer. X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS) analyses confirmed the formation of rhenium carbides, elemental rhenium, and rhenium oxides within the coatings. Despite these successful depositions, scanning electron microscopy (SEM) revealed significant delamination and poor adhesion of the coatings to the Ti6Al4V substrates. Corrosion resistance, evaluated through potentiodynamic polarization tests, showed an increase in corrosion current densities and more negative corrosion potentials, indicating a detrimental effect on the substrate’s corrosion resistance. Biocompatibility assessments using PK15 cells demonstrated a marked decrease in cell viability and metabolic activity, particularly in samples with higher surface roughness. These findings underscore the critical need for the optimization of surface preparation and deposition processes to improve both the adhesion and biocompatibility of rhenium–carbon coatings on Ti6Al4V substrates. Future research should aim to refine coating technique to enhance adhesion, explore the mechanisms of cytotoxicity related to surface roughness, and expand biocompatibility studies across different cell lines and biological environments.

MetalsVol. 14(10)
Pedagogical and Technological University of Colombia (CO), Military University Nueva Granada (CO), Escuela Colombiana de Carreras Industriales (CO)
Openalex Percentile: Top 84%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.