Comparative Analysis of Armature Structure on Constant Force Characteristics in Long-Stroke Moving-Iron Proportional Solenoid Actuator

The influence of key design parameters on the constant force characteristics of long-stroke moving-iron proportional solenoid actuators (MPSAs) has been explored by a method combining finite element modelling and correlation analysis. First, the finite element model (FEM) of long-stroke MPSA was developed and validated. Subsequently, the two evaluation indexes, the average-output solenoid force and maximum-output solenoid force variability, were introduced to disclose the influence law of pole shoe parameters on the constant force characteristics of a long-stroke MPSA. After that, correlation analysis was employed to quantify the influence of several parameters and parameter interaction factors on the constant force characteristics. The results indicate a strong contradiction between the average-output solenoid force and maximum-output solenoid force variability; however, increasing the inner diameter of the cone helps enhance the average-output solenoid force without causing maximum-output solenoid force variability to increase. Among all the parameters examined, the cone angle is the most significant parameter affecting the constant force characteristics. Additionally, interactions between the cone angle and the cone length, the cone angle and the inner cone diameter, the cone angle and the outer cone diameter, the cone length and the outer cone diameter, as well as the inner cone diameter and the outer cone diameter also have an important influence on the constant force characteristics. This study deepens our understanding of how the key parameters affect the constant force characteristics and assists designers in optimizing these parameters for developing new structures.

Authors

Institutions

Publication Details

Journal
Actuators
Published
2024-10-08
DOI
https://doi.org/10.3390/act13100408
Citations
1
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Armature Structure on Constant Force Characteristics in Long-Stroke Moving-Iron Proportional Solenoid Actuator

Yuwen Ouyang, Rongkai Shang, Wenwen Quan, Peng Liu
1 citations
Actuators
Hydraulic and Pneumatic Systems
0.21
article

Comparative Analysis of Armature Structure on Constant Force Characteristics in Long-Stroke Moving-Iron Proportional Solenoid Actuator

Yuwen Ouyang, Rongkai Shang, Wenwen Quan, Peng Liu
article en
1 citations

Abstract

The influence of key design parameters on the constant force characteristics of long-stroke moving-iron proportional solenoid actuators (MPSAs) has been explored by a method combining finite element modelling and correlation analysis. First, the finite element model (FEM) of long-stroke MPSA was developed and validated. Subsequently, the two evaluation indexes, the average-output solenoid force and maximum-output solenoid force variability, were introduced to disclose the influence law of pole shoe parameters on the constant force characteristics of a long-stroke MPSA. After that, correlation analysis was employed to quantify the influence of several parameters and parameter interaction factors on the constant force characteristics. The results indicate a strong contradiction between the average-output solenoid force and maximum-output solenoid force variability; however, increasing the inner diameter of the cone helps enhance the average-output solenoid force without causing maximum-output solenoid force variability to increase. Among all the parameters examined, the cone angle is the most significant parameter affecting the constant force characteristics. Additionally, interactions between the cone angle and the cone length, the cone angle and the inner cone diameter, the cone angle and the outer cone diameter, the cone length and the outer cone diameter, as well as the inner cone diameter and the outer cone diameter also have an important influence on the constant force characteristics. This study deepens our understanding of how the key parameters affect the constant force characteristics and assists designers in optimizing these parameters for developing new structures.

ActuatorsVol. 13(10)
Yingkou Institute of Technology (CN), Changsha University of Science and Technology (CN)
Openalex Percentile: Top 51%
Hydraulic and Pneumatic Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.