Overcoming the Strong Sample Solvent Effect for Sustainability Measurement Challenges in Liquid Chromatography. Example for Bisphenol-A

This paper describes an approach to achieve low parts per billion (ppb) concentration level detection using a reversed-phase ultrahigh-performance liquid chromatographic ultraviolet absorbance detection method with large-volume feed injection (FI) for analytes in dichloromethane (DCM). FI is a novel technology that allows sample injection at a defined speed into the LC mobile phase. We demonstrate this approach for a mixture of bisphenol A and its diglycidyl ether derivatives in DCM. DCM is a very strong injection solvent at reversed-phase LC conditions and is typically immiscible with a starting reversed-phase gradient mobile phase containing a high percentage of water. As a result, reduced separation performance and even peak splitting are seen with classic flow-through injection. The method setup comprised an octyl-bonded core-shell stationary phase (150 × 4.6 mm i.d., 2.7 μm particle size) with a water/acetonitrile mobile phase gradient and an exceptionally high injection volume of 45 μL of DCM solution using FI. Optimization of feed speed (1%) and isocratic hold duration (4 min) was crucial for final separation conditions. FI delivered more than a 20-fold improvement in the limit of detection (LOD) compared to standard flow-through injection while maintaining peak resolution. The LOD of the final method ranged between 1 and 10 ppb in the polymer resin. This methodology has high potential for trace analysis in a large variety of applications that suffer from the "strong solvent effect".

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-08
DOI
https://doi.org/10.1021/acs.analchem.4c03624
Citations
4
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overcoming the Strong Sample Solvent Effect for Sustainability Measurement Challenges in Liquid Chromatography. Example for Bisphenol-A

Matthias Pursch, Hannes Georg Graf, Peilin Yang, Edgar Naegele et al.
4 citations
Analytical Chemistry
Analytical Chemistry and Chromatography
0.96
article

Overcoming the Strong Sample Solvent Effect for Sustainability Measurement Challenges in Liquid Chromatography. Example for Bisphenol-A

Matthias Pursch, Hannes Georg Graf, Peilin Yang, Edgar Naegele, Shayne Green, Jingchun Yang, Thomas Ortmann
article en
4 citations

Abstract

This paper describes an approach to achieve low parts per billion (ppb) concentration level detection using a reversed-phase ultrahigh-performance liquid chromatographic ultraviolet absorbance detection method with large-volume feed injection (FI) for analytes in dichloromethane (DCM). FI is a novel technology that allows sample injection at a defined speed into the LC mobile phase. We demonstrate this approach for a mixture of bisphenol A and its diglycidyl ether derivatives in DCM. DCM is a very strong injection solvent at reversed-phase LC conditions and is typically immiscible with a starting reversed-phase gradient mobile phase containing a high percentage of water. As a result, reduced separation performance and even peak splitting are seen with classic flow-through injection. The method setup comprised an octyl-bonded core-shell stationary phase (150 × 4.6 mm i.d., 2.7 μm particle size) with a water/acetonitrile mobile phase gradient and an exceptionally high injection volume of 45 μL of DCM solution using FI. Optimization of feed speed (1%) and isocratic hold duration (4 min) was crucial for final separation conditions. FI delivered more than a 20-fold improvement in the limit of detection (LOD) compared to standard flow-through injection while maintaining peak resolution. The LOD of the final method ranged between 1 and 10 ppb in the polymer resin. This methodology has high potential for trace analysis in a large variety of applications that suffer from the "strong solvent effect".

Analytical ChemistryVol. 96(42)
Agilent Technologies (Germany) (DE), Hewlett-Packard (Germany) (DE)
Responsible consumption and production
Openalex Percentile: Top 27%
Analytical Chemistry and Chromatography
0.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.