Low-Cost Purpose-Built Ultra-Low-Field NMR Spectrometer
Low-field NMR has emerged as a new analytical technique for the investigation of molecular structure and dynamics. Here, we introduce a highly integrated ultralow-frequency NMR spectrometer designed for the purpose of ultralow-field NMR polarimetry of hyperpolarized contrast media. The device measures 10 cm × 10 cm × 2.0 cm and weighs only 370 g. The spectrometer's aluminum enclosure contains all components, including an RF amplifier. The device has four ports for connecting to a high-impedance RF transmit-receive coil, a trigger input, a USB port for connectivity to a PC computer, and an auxiliary RS-485/24VDC port for system integration with other devices. The NMR spectrometer is configured for a pulse-wait-acquire-recover pulse sequence, and key sequence parameters are readily controlled by a graphical user interface (GUI) of a Windows-based PC computer. The GUI also displays the time-domain and Fourier-transformed NMR signal and allows autosaving of NMR data as a CSV file. Alternatively, the RS485 communication line allows for operating the device with sequence parameter control and data processing directly on the spectrometer board in a fully automated and integrated manner. The NMR spectrometer, equipped with a 250 ksamples/s 17-bit analog-to-digital signal converter, can perform acquisition in the 1-125 kHz frequency range. The utility of the device is demonstrated for NMR polarimetry of hyperpolarized <sup>129</sup>Xe gas and [1-<sup>13</sup>C]pyruvate contrast media (which was compared to the <sup>13</sup>C polarimetry using a more established technology of benchtop <sup>13</sup>C NMR spectroscopy, and yielded similar results), allowing reproducible quantification of polarization values and relaxation dynamics. The cost of the device components is only ∼$200, offering a low-cost integrated NMR spectrometer that can be deployed as a plug-and-play device for a wide range of applications in hyperpolarized contrast media production─and beyond.
Authors
- Md Raduanul H. Chowdhury (ORCID: https://orcid.org/0000-0002-7007-6794)
- Panayiotis Nikolaou (ORCID: https://orcid.org/0000-0002-3802-0803)
- Boyd M. Goodson (ORCID: https://orcid.org/0000-0001-6079-5077)
- Abubakar Abdurraheem (ORCID: https://orcid.org/0000-0002-3916-8834)
- Yuri A. Chekmenev
- Jonathan R. Birchall (ORCID: https://orcid.org/0000-0003-3920-4038)
- Shiraz Nantogma (ORCID: https://orcid.org/0000-0002-2655-6256)
- Michael J. Barlow (ORCID: https://orcid.org/0000-0003-3609-6043)
- Anton Shcherbakov
- Eduard Y. Chekmenev (ORCID: https://orcid.org/0000-0002-8745-8801)
- Isaiah Adelabu (ORCID: https://orcid.org/0000-0002-9475-0851)
- Clementinah Oladun (ORCID: https://orcid.org/0000-0003-0621-5590)
- Firoz Ahmed (ORCID: https://orcid.org/0000-0003-1469-8035)
- Tobi Abdulbasit Gafar
Institutions
- Southern Illinois University Carbondale (US)
- University of Nottingham (GB)
- Wayne State University (US)
- The Barbara Ann Karmanos Cancer Institute (US)
- XeUS Technologies (Cyprus) (CY)
Publication Details
- Journal
- Analytical Chemistry
- Published
- 2024-10-08
- DOI
- https://doi.org/10.1021/acs.analchem.4c03149
- Citations
- 5
- Primary Topic
- Advanced NMR Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.20
Funders
- National Science Foundation
- U.S. Department of Defense
- Research Corporation for Science Advancement
- Wayne State University
- James Tudor Foundation
- National Institute of Biomedical Imaging and Bioengineering
- Division of Chemistry
- Congressionally Directed Medical Research Programs