Statistical Estimates of Intentional Electromagnetic Interference in Unshielded Twisted-Wire Pairs

A recently developed worst-case/statistical approach to assessment of radiated intentional electromagnetic interference (IEMI) in general multiport systems is here applied to the special case of an unshielded twisted-wire pair (TWP). Worst-case analysis overcomes lack of knowledge on the waveform of the electromagnetic pulse, while statistics take into account the random incidence and polarization angle of the impinging plane wave, as well as non-uniformity of wire twisting. The worst-case peak of the induced-voltage waveform and the worst-case dissipated energy in TWP terminal loads are characterized through cumulative distribution functions. Significant properties are inferred with reference to common-mode and differential-mode quantities.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/iceaa61917.2024.10701846
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Statistical Estimates of Intentional Electromagnetic Interference in Unshielded Twisted-Wire Pairs

Giordano Spadacini, Sergio A. Pignari, Yan‐Zhao Xie, Tao Liang et al.
Induction Heating and Inverter Technology
article

Statistical Estimates of Intentional Electromagnetic Interference in Unshielded Twisted-Wire Pairs

Giordano Spadacini, Sergio A. Pignari, Yan‐Zhao Xie, Tao Liang, Flavia Grassi
article en

Abstract

A recently developed worst-case/statistical approach to assessment of radiated intentional electromagnetic interference (IEMI) in general multiport systems is here applied to the special case of an unshielded twisted-wire pair (TWP). Worst-case analysis overcomes lack of knowledge on the waveform of the electromagnetic pulse, while statistics take into account the random incidence and polarization angle of the impinging plane wave, as well as non-uniformity of wire twisting. The worst-case peak of the induced-voltage waveform and the worst-case dissipated energy in TWP terminal loads are characterized through cumulative distribution functions. Significant properties are inferred with reference to common-mode and differential-mode quantities.

Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 83%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.