A ribbon figure-8 coil design for scalable and selective Trans-Spinal Magnetic Stimulation (TSMS)

Trans-Spinal Magnetic Stimulation (TSMS) is gaining attention in medical research as a promising, non-invasive alternative to conventional treatments for refractory chronic neuropathic back pain, such as spinal cord stimulation (SCS) [1–2]. Through a time-varying magnetic field, TSMS delivers electrical pulses to the spinal cord through a coil positioned on the patient’s back. The stimulation must be focal and penetrate deeply enough to reach the spinal cord, which may vary in depth depending on the individual [3]. The various commercial TSMS coils are built by winding metal wires with different numbers of turns, which affect the inductance of the coil. The winding wire diameter may be increased to allow for larger currents and increase the magnetic field, $\mathbf{B}$, more profoundly in the tissue. In that case, the coil diameter tends to increase (Fig. 1A), and there may be a loss of focality and, consequently, a lower fiber selectivity.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/iceaa61917.2024.10701683
Citations
1
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A ribbon figure-8 coil design for scalable and selective Trans-Spinal Magnetic Stimulation (TSMS)

L Gómez-Cid, Francesca Marturano, İlknur Ay, Giorgio Bonmassar
1 citations
Transcranial Magnetic Stimulation Studies
0.25
article

A ribbon figure-8 coil design for scalable and selective Trans-Spinal Magnetic Stimulation (TSMS)

L Gómez-Cid, Francesca Marturano, İlknur Ay, Giorgio Bonmassar
article en
1 citations

Abstract

Trans-Spinal Magnetic Stimulation (TSMS) is gaining attention in medical research as a promising, non-invasive alternative to conventional treatments for refractory chronic neuropathic back pain, such as spinal cord stimulation (SCS) [1–2]. Through a time-varying magnetic field, TSMS delivers electrical pulses to the spinal cord through a coil positioned on the patient’s back. The stimulation must be focal and penetrate deeply enough to reach the spinal cord, which may vary in depth depending on the individual [3]. The various commercial TSMS coils are built by winding metal wires with different numbers of turns, which affect the inductance of the coil. The winding wire diameter may be increased to allow for larger currents and increase the magnetic field, $\mathbf{B}$, more profoundly in the tissue. In that case, the coil diameter tends to increase (Fig. 1A), and there may be a loss of focality and, consequently, a lower fiber selectivity.

Harvard University (US), Massachusetts General Hospital (US), Athinoula A. Martinos Center for Biomedical Imaging (US)
Affordable and clean energy
Openalex Percentile: Top 43%
Transcranial Magnetic Stimulation Studies
0.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.