Conformal Electromagnetic Skin Based on Flexible Materials

In the last years the diffusion of wireless sensors for health related applications is increasing exponentially. The unlicensed millimeter-wave (mmW) band around 60 GHz offers advantages in terms of miniaturization and wide bandwidth. Since these devices operate in contact or in proximity of the human body, they need to be tested in real exposure condition. While for ethical reasons compliance testing is not performed directly on human beings, it is possible to use phantoms that reproduce the electromagnetic (EM) properties of biological tissues. Compared to liquid [1] and semisolid phantoms [2], solid phantoms have the advantage to be long lasting and do not require any shell [3]. However, at mmW it is challenging to find a combination of materials that allow to match the permittivity of the skin (ε<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">r</inf> = 7.98 – j 10.90) without using water. The only available solution are solid, but rigid phantoms, that are representative only for a predefined posture of the body. As an alternative solution, this paper proposes a skin-equivalent solid and flexible phantom that reproduces the reflection coefficient at the air/skin interface in the 55-65 GHz range. The phantom consists in a 2.1-mm layer of silicone and carbon powder (40% of the composite weight) backed by an electrotextile (Fig.la). The thickness of the silicone/carbon layer is optimized to approach the skin reflection coefficient when considering a transverse magnetic (TM) or transverse electric (TE) impinging plane wave for the angles of incidence from 0° to 60°. The maximum relative error between the reflection coefficient of the realized phantom and the skin is 2.6% for the magnitude and 13%. The phantom has been experimentally validated using a free-space transmission/reflection system. The measurement results of the magnitude of the reflection coefficient for normal incidence (see Figure lb) are in good agreement with numerical simulations, showing a relative error within 1.9% in the 55-65 GHz range. Such a phantom represents a promising solution for body-centric measurements where reconfigurable, flexible, conformal or dynamic body models are necessary.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/iceaa61917.2024.10701842
Primary Topic
Antenna Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conformal Electromagnetic Skin Based on Flexible Materials

Giulia Sacco, R. Rizzo, Giuseppe Ruello, Maxim Zhadobov et al.
Antenna Design and Analysis
article

Conformal Electromagnetic Skin Based on Flexible Materials

Giulia Sacco, R. Rizzo, Giuseppe Ruello, Maxim Zhadobov, Rita Massa
article en

Abstract

In the last years the diffusion of wireless sensors for health related applications is increasing exponentially. The unlicensed millimeter-wave (mmW) band around 60 GHz offers advantages in terms of miniaturization and wide bandwidth. Since these devices operate in contact or in proximity of the human body, they need to be tested in real exposure condition. While for ethical reasons compliance testing is not performed directly on human beings, it is possible to use phantoms that reproduce the electromagnetic (EM) properties of biological tissues. Compared to liquid [1] and semisolid phantoms [2], solid phantoms have the advantage to be long lasting and do not require any shell [3]. However, at mmW it is challenging to find a combination of materials that allow to match the permittivity of the skin (ε<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">r</inf> = 7.98 – j 10.90) without using water. The only available solution are solid, but rigid phantoms, that are representative only for a predefined posture of the body. As an alternative solution, this paper proposes a skin-equivalent solid and flexible phantom that reproduces the reflection coefficient at the air/skin interface in the 55-65 GHz range. The phantom consists in a 2.1-mm layer of silicone and carbon powder (40% of the composite weight) backed by an electrotextile (Fig.la). The thickness of the silicone/carbon layer is optimized to approach the skin reflection coefficient when considering a transverse magnetic (TM) or transverse electric (TE) impinging plane wave for the angles of incidence from 0° to 60°. The maximum relative error between the reflection coefficient of the realized phantom and the skin is 2.6% for the magnitude and 13%. The phantom has been experimentally validated using a free-space transmission/reflection system. The measurement results of the magnitude of the reflection coefficient for normal incidence (see Figure lb) are in good agreement with numerical simulations, showing a relative error within 1.9% in the 55-65 GHz range. Such a phantom represents a promising solution for body-centric measurements where reconfigurable, flexible, conformal or dynamic body models are necessary.

Centre National de la Recherche Scientifique (FR), Institut d'Électronique et des Technologies du numéRique (FR), Université de Rennes (FR), University of Naples Federico II (IT)
HORIZON EUROPE Framework Programme
Affordable and clean energy
Openalex Percentile: Top 73%
Antenna Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.