Research on electromagnetic compatibility of maglev train on high-speed maglev demonstration line

Taking maglev train of high speed maglev demonstration line as the research object, the electromagnetic compatibility performance of this train is analyzed. The magnetic field of external electromagnetic radiation emitted by the vehicle in the frequency range of 150kHz-30MHz and the electric field emitted by the vehicle in the frequency range of 30MHz-1GHz are tested. The magnetic flux density (DC-20kHz) of the guest room area was tested and the electromagnetic protection requirements for the public and professional personnel were assessed. The test results show that the magnetic field and electric field radiated by the vehicle meet the limit requirements, and the magnetic flux density in the passenger room also meets the standard limit requirements.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/iceaa61917.2024.10701717
Primary Topic
Magnetic Bearings and Levitation Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on electromagnetic compatibility of maglev train on high-speed maglev demonstration line

Jin Bao Zhang, Zhi Qiang Zhang, Xiao Jia, T. Su et al.
1 links
Magnetic Bearings and Levitation Dynamics
article

Research on electromagnetic compatibility of maglev train on high-speed maglev demonstration line

Jin Bao Zhang, Zhi Qiang Zhang, Xiao Jia, T. Su, Shi Xiao
article en

Abstract

Taking maglev train of high speed maglev demonstration line as the research object, the electromagnetic compatibility performance of this train is analyzed. The magnetic field of external electromagnetic radiation emitted by the vehicle in the frequency range of 150kHz-30MHz and the electric field emitted by the vehicle in the frequency range of 30MHz-1GHz are tested. The magnetic flux density (DC-20kHz) of the guest room area was tested and the electromagnetic protection requirements for the public and professional personnel were assessed. The test results show that the magnetic field and electric field radiated by the vehicle meet the limit requirements, and the magnetic flux density in the passenger room also meets the standard limit requirements.

Beijing Jiaotong University (CN), Qingdao Center of Resource Chemistry and New Materials (CN)
Affordable and clean energy
Openalex Percentile: Top 80%
Magnetic Bearings and Levitation Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.