Optimized control strategy for a three-phase grid connected inverter using PI controller and DQ frame

This paper provides a proportional-integral (PI) controller and direct-quadrature (DQ) frame transformation-based optimum control method for a three-phase grid-connected inverter. In terms of grid synchronization, voltage regulation, and harmonic abatement, the proposed control technique attempts to improve the inverter's performance. By separating the control of active and reactive power, the control structure is made simpler and independent regulation of these parameters is possible. This improves the inverter's capacity to quickly react to grid disruptions and track reference values accurately. In order to lower carbon emissions and improve grid dependability, it has become vital to integrate renewable energy sources into the current power grid. Grid-connected inverters are essential in this situation because they transform DC electricity from renewable sources into grid-safe AC power. This abstract outline a proportional-integral (PI) controller and direct-quadrature (DQ) frame-based optimal control method for a three-phase grid-connected inverter using a MATLAB simulation.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Power Engineering (IJAPE)
Published
2024-10-08
DOI
https://doi.org/10.11591/ijape.v13.i4.pp790-797
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized control strategy for a three-phase grid connected inverter using PI controller and DQ frame

V R Kavya, Nagasridhar Arise, M. Deepu Vijay, Madde Saiteja et al.
International Journal of Applied Power Engineering (IJAPE)
Microgrid Control and Optimization
article

Optimized control strategy for a three-phase grid connected inverter using PI controller and DQ frame

V R Kavya, Nagasridhar Arise, M. Deepu Vijay, Madde Saiteja, V. Siddu
article en

Abstract

This paper provides a proportional-integral (PI) controller and direct-quadrature (DQ) frame transformation-based optimum control method for a three-phase grid-connected inverter. In terms of grid synchronization, voltage regulation, and harmonic abatement, the proposed control technique attempts to improve the inverter's performance. By separating the control of active and reactive power, the control structure is made simpler and independent regulation of these parameters is possible. This improves the inverter's capacity to quickly react to grid disruptions and track reference values accurately. In order to lower carbon emissions and improve grid dependability, it has become vital to integrate renewable energy sources into the current power grid. Grid-connected inverters are essential in this situation because they transform DC electricity from renewable sources into grid-safe AC power. This abstract outline a proportional-integral (PI) controller and direct-quadrature (DQ) frame-based optimal control method for a three-phase grid-connected inverter using a MATLAB simulation.

International Journal of Applied Power Engineering (IJAPE)Vol. 13(4)
Gokula Krishna College of Pharmacy (IN)
Openalex Percentile: Top 80%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines