Assessing transformer health through analysis of dissolved gases in cooling oil

Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Power Engineering (IJAPE)
Published
2024-10-08
DOI
https://doi.org/10.11591/ijape.v13.i4.pp1014-1020
Citations
1
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing transformer health through analysis of dissolved gases in cooling oil

I Made Ari Nrartha, Sapto Nisworo, Arnawan Hasibuan, Muzamir Isa et al.
1 citations
International Journal of Applied Power Engineering (IJAPE)
Power Transformer Diagnostics and Insulation
0.21
article

Assessing transformer health through analysis of dissolved gases in cooling oil

I Made Ari Nrartha, Sapto Nisworo, Arnawan Hasibuan, Muzamir Isa, Misbahul Jannah, Muhammad Muhammad
article en
1 citations

Abstract

Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.

International Journal of Applied Power Engineering (IJAPE)Vol. 13(4)
University of Mataram (ID), Malikussaleh University (ID), Universitas Tidar (ID), Universiti Malaysia Perlis (MY)
Openalex Percentile: Top 47%
Power Transformer Diagnostics and Insulation
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing transformer health through analysis of dissolved gases in cooling oil — I Made Ari Nrartha, Sapto Nisworo, et al. · International Journal of Applied Power Engineering (IJAPE) (2024) | TGRS Research Map | TGRS