Multilayer patch functionalized microfibrillated cellulosic paper sensor for sweat glucose monitoring

Electrochemical analysis of glucose monitoring without painful blood collection provides a new noninvasive route for monitoring glucose levels. Thus, in this study, biobased cellulosic papers (methylated and phosphorylated one) based glucose monitoring sensor is developed. To achieve high hydrophilicity, microfibrillated cellulose (MFC) were functionalized using hexokinase mediated phosphorylation (-OH to -[Formula: see text]). The instinctive increased surface charge density from 36.2 ± 3.4 to 118.4 ± 1.2 µmol/g and decrease contact angle (45°-22°) confirms the increased hydrophilicity of paper. Furthermore, functionalized phos-MFC paper increase the capillary flow of sweat, required low quantity (1 µl) of sweat for accurate analysis of glucose level. Additionally, chemically induced methyl groups (-CH<sub>3</sub>) make the sensor more barrier to other chemicals. In addition, a multilayer patch design combined with sensor miniaturization was used to lead to an increase in the efficiency of the sweat collection and sensing processes. Besides, this paper sensor integrated with artificial transdermal drug delivery unit (agarose gel as skin) for monitoring glucose levels in sweat. The patch monitoring system increase the accuracy of sensing with fluctuation in sweat vol. (1-4 µl), temperature (20-70 °C), and pH (4.0-7.0). In addition, temperature dependency artificial transdermal delivery (within agarose gel) of drug metformin agrees the measurement accuracy of sensor, called "switch system" without any error. As a result, the reported MFC paper based multi-patch disposable sensing system provides a novel closed-loop solution for the noninvasive sweat-based management of diabetes mellitus.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-08
DOI
https://doi.org/10.1038/s41598-024-74899-z
Citations
5
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multilayer patch functionalized microfibrillated cellulosic paper sensor for sweat glucose monitoring

Faheem Ahmed, Zoheb Karim, Mohd Jahir Khan, Zishan H. Khan et al.
5 citations
Scientific Reports
Advanced Sensor and Energy Harvesting Materials
0.92
article

Multilayer patch functionalized microfibrillated cellulosic paper sensor for sweat glucose monitoring

Faheem Ahmed, Zoheb Karim, Mohd Jahir Khan, Zishan H. Khan, Afzal Hussain
article en
5 citations

Abstract

Electrochemical analysis of glucose monitoring without painful blood collection provides a new noninvasive route for monitoring glucose levels. Thus, in this study, biobased cellulosic papers (methylated and phosphorylated one) based glucose monitoring sensor is developed. To achieve high hydrophilicity, microfibrillated cellulose (MFC) were functionalized using hexokinase mediated phosphorylation (-OH to -[Formula: see text]). The instinctive increased surface charge density from 36.2 ± 3.4 to 118.4 ± 1.2 µmol/g and decrease contact angle (45°-22°) confirms the increased hydrophilicity of paper. Furthermore, functionalized phos-MFC paper increase the capillary flow of sweat, required low quantity (1 µl) of sweat for accurate analysis of glucose level. Additionally, chemically induced methyl groups (-CH<sub>3</sub>) make the sensor more barrier to other chemicals. In addition, a multilayer patch design combined with sensor miniaturization was used to lead to an increase in the efficiency of the sweat collection and sensing processes. Besides, this paper sensor integrated with artificial transdermal drug delivery unit (agarose gel as skin) for monitoring glucose levels in sweat. The patch monitoring system increase the accuracy of sensing with fluctuation in sweat vol. (1-4 µl), temperature (20-70 °C), and pH (4.0-7.0). In addition, temperature dependency artificial transdermal delivery (within agarose gel) of drug metformin agrees the measurement accuracy of sensor, called "switch system" without any error. As a result, the reported MFC paper based multi-patch disposable sensing system provides a novel closed-loop solution for the noninvasive sweat-based management of diabetes mellitus.

Scientific ReportsVol. 14(1)
Mahidol University (TH), King Saud University (SA), Ornsköldsvik Hospital (SE), Jamia Millia Islamia (IN)
King Saud University
Openalex Percentile: Top 28%
Advanced Sensor and Energy Harvesting Materials
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.