Impact of the frequency error of direct digital synthesizers on the evaluation of two-photon light shift in atom gravimeters

One major systematic error for free-fall atom gravimeters is the effect of two-photon light shift (LS2). In the process of evaluating LS2, the results can be affected by the residual frequency error of direct digital synthesizers due to necessary experimental parameter changes. In this paper, the impact of the coupling effect between the frequency error and LS2 has been investigated and analyzed, along with the related physical mechanisms. The parameters of the frequency error sequence, such as the time step of δt and the time delay of Δt, significantly affect the bias and uncertainty of LS2. Notably, when these parameters are significantly altered or misaligned, the impact can reach several tens of µGal. Conversely, when they remain within the optimal ranges, the impact can be minimal. Specifically, when δt is less than or equal to 10 µs, the impact on the LS2 bias is less than 0.3 µGal, with the contribution to the total uncertainty of the gravity value being approximately 0.1 µGal. Furthermore, after correcting the phase shift introduced by the frequency error, the evaluation results have a similar improvement effect on the whole. Compared to the LS2 theoretical value, the residual is generally on the order of µGal. Through the comprehensive analysis and optimization, as well as related experiments, this cross-effect is managed and decoupled, leading to accurate LS2 evaluation results. This improvement ensures a better accuracy in the obtained absolute gravity values. The analysis methods discussed can provide an effective strategy for enhancing the performance of atom gravimeters.

Authors

Publication Details

Journal
Optics Express
Published
2024-10-08
DOI
https://doi.org/10.1364/oe.535455
Citations
5
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
2.31

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of the frequency error of direct digital synthesizers on the evaluation of two-photon light shift in atom gravimeters

Li-Ming Wu, Bing‐Ming Cheng, Naike Liu, Qiang Lin et al.
5 citations
Optics Express
Scientific Measurement and Uncertainty Evaluation
2.31
article

Impact of the frequency error of direct digital synthesizers on the evaluation of two-photon light shift in atom gravimeters

Li-Ming Wu, Bing‐Ming Cheng, Naike Liu, Qiang Lin, Xiaolong Wang, Dong Zhu, Kainan Wang, Yin Zhou, Bin Wu, J. G. Bian, Pengfei Cao, Kanxing Weng
article en
5 citations

Abstract

One major systematic error for free-fall atom gravimeters is the effect of two-photon light shift (LS2). In the process of evaluating LS2, the results can be affected by the residual frequency error of direct digital synthesizers due to necessary experimental parameter changes. In this paper, the impact of the coupling effect between the frequency error and LS2 has been investigated and analyzed, along with the related physical mechanisms. The parameters of the frequency error sequence, such as the time step of δt and the time delay of Δt, significantly affect the bias and uncertainty of LS2. Notably, when these parameters are significantly altered or misaligned, the impact can reach several tens of µGal. Conversely, when they remain within the optimal ranges, the impact can be minimal. Specifically, when δt is less than or equal to 10 µs, the impact on the LS2 bias is less than 0.3 µGal, with the contribution to the total uncertainty of the gravity value being approximately 0.1 µGal. Furthermore, after correcting the phase shift introduced by the frequency error, the evaluation results have a similar improvement effect on the whole. Compared to the LS2 theoretical value, the residual is generally on the order of µGal. Through the comprehensive analysis and optimization, as well as related experiments, this cross-effect is managed and decoupled, leading to accurate LS2 evaluation results. This improvement ensures a better accuracy in the obtained absolute gravity values. The analysis methods discussed can provide an effective strategy for enhancing the performance of atom gravimeters.

Optics ExpressVol. 32(23)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 11%
Scientific Measurement and Uncertainty Evaluation
2.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.