Targeted K‐Edge Nanoprobes From Praseodymium and Hafnium for Ratiometric Tracking of Dual Biomarkers using Spectral Photon Counting CT

Utilizing metal nanoprobes with unique K-edge identities to visualize complementary biological activities simultaneously can provide valuable information about complex biological processes. This study describes the design and preparation of an innovative pair of K-edge metal nanoprobes and demonstrates the feasibility of their simultaneous quantitative detection using spectral photon-counting computed tomography (SPCCT). Glycosaminoglycan (GAG) capped nanoparticles (ca. 15-20 nm) targeting two distinct components of the cartilage tissue, namely, aggrecan (acan) and aggrecanase (acanase) are designed and synthesized. These targeted nanoparticles comprised of praseodymium (Pr) and hafnium (Hf), with well-separated K-edge energies, enable simultaneous and ratiometric imaging of dual biomarkers in cartilage tissue. Following extensive physico-chemical characterization of the ligand-targeted particles, the feasibility of homing dual biomarkers in vitro is demonstrated. The material discrimination and simultaneous quantification of these targeted particles are also achieved and corroborated with inductively coupled plasmon spectroscopy. For the first time, the use of praseodymium is reported as a contrast agent for SPCCT imaging and demonstrates the ability to pair it with hafnium nanoprobes for multicontrast imaging of diseases. Importantly, the potential for ratiometric molecular imaging and tracking of osteoarthritis (OA) progression is shown with SPCCT K-edge based imaging approach.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2024-10-07
DOI
https://doi.org/10.1002/advs.202408408
Citations
8
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Targeted K‐Edge Nanoprobes From Praseodymium and Hafnium for Ratiometric Tracking of Dual Biomarkers using Spectral Photon Counting CT

Fadia Kamal, Pranay Saha, Dipanjan Pan, Mahdieh Moghiseh et al.
8 citations
Advanced Science
Advanced X-ray and CT Imaging
1.48
article

Targeted K‐Edge Nanoprobes From Praseodymium and Hafnium for Ratiometric Tracking of Dual Biomarkers using Spectral Photon Counting CT

Fadia Kamal, Pranay Saha, Dipanjan Pan, Mahdieh Moghiseh, Kevin Jonker, Steven P. Gieseg, Parikshit Moitra, Anthony Butler, Teresa Aditya, Nivetha Gunaseelan
article en
8 citations

Abstract

Utilizing metal nanoprobes with unique K-edge identities to visualize complementary biological activities simultaneously can provide valuable information about complex biological processes. This study describes the design and preparation of an innovative pair of K-edge metal nanoprobes and demonstrates the feasibility of their simultaneous quantitative detection using spectral photon-counting computed tomography (SPCCT). Glycosaminoglycan (GAG) capped nanoparticles (ca. 15-20 nm) targeting two distinct components of the cartilage tissue, namely, aggrecan (acan) and aggrecanase (acanase) are designed and synthesized. These targeted nanoparticles comprised of praseodymium (Pr) and hafnium (Hf), with well-separated K-edge energies, enable simultaneous and ratiometric imaging of dual biomarkers in cartilage tissue. Following extensive physico-chemical characterization of the ligand-targeted particles, the feasibility of homing dual biomarkers in vitro is demonstrated. The material discrimination and simultaneous quantification of these targeted particles are also achieved and corroborated with inductively coupled plasmon spectroscopy. For the first time, the use of praseodymium is reported as a contrast agent for SPCCT imaging and demonstrates the ability to pair it with hafnium nanoprobes for multicontrast imaging of diseases. Importantly, the potential for ratiometric molecular imaging and tracking of osteoarthritis (OA) progression is shown with SPCCT K-edge based imaging approach.

Advanced ScienceVol. 11(46)
University of Maryland, Baltimore (US), Pennsylvania State University (US), University of Canterbury (NZ), Christchurch Clinical Studies Trust (NZ), Center for Orthopaedics (US), University of Maryland, Baltimore County (US), University of Otago (NZ), Penn State Milton S. Hershey Medical Center (US)
National Science Foundation, U.S. Department of Defense, Centers for Disease Control and Prevention, Congressionally Directed Medical Research Programs
Peace, Justice and strong institutions
Openalex Percentile: Top 19%
Advanced X-ray and CT Imaging
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.