Combining Infrared Refraction and Attenuated Total Reflection Spectroscopy

We have specified and obtained a ZnSe prism with an unconventional face angle cut to 30°. This prism, with internal incidence angles ranging from 30° to 48°, allows users to record internal reflection spectra below the critical angle and attenuated total reflection (ATR) spectra above the critical angle without the need to change optics or move or replace the sample. We demonstrate its capabilities using 102 spectra of benzyl benzoate taken with <i>s</i>- and <i>p</i>-polarization at different angles of incidence. The subcritical spectra were analyzed to obtain <i>n</i><sub>∞</sub>, a key parameter for correcting the ATR spectra. These corrected spectra were subsequently used to determine the complex refractive index for all ATR measurements. The averaged complex refractive index function shows excellent agreement with that obtained through ATR spectroscopic ellipsometry.

Authors

Institutions

Publication Details

Journal
Applied Spectroscopy
Published
2024-10-07
DOI
https://doi.org/10.1177/00037028241283050
Citations
10
Primary Topic
Spectroscopy and Quantum Chemical Studies
Type
article
Field-Weighted Citation Impact
3.38
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining Infrared Refraction and Attenuated Total Reflection Spectroscopy

Jürgen Popp, Thomas G. Mayerhöfer, William D. P. Costa
10 citations
Applied Spectroscopy
Spectroscopy and Quantum Chemical Studies
3.38
article

Combining Infrared Refraction and Attenuated Total Reflection Spectroscopy

Jürgen Popp, Thomas G. Mayerhöfer, William D. P. Costa
article en
10 citations

Abstract

We have specified and obtained a ZnSe prism with an unconventional face angle cut to 30°. This prism, with internal incidence angles ranging from 30° to 48°, allows users to record internal reflection spectra below the critical angle and attenuated total reflection (ATR) spectra above the critical angle without the need to change optics or move or replace the sample. We demonstrate its capabilities using 102 spectra of benzyl benzoate taken with <i>s</i>- and <i>p</i>-polarization at different angles of incidence. The subcritical spectra were analyzed to obtain <i>n</i><sub>∞</sub>, a key parameter for correcting the ATR spectra. These corrected spectra were subsequently used to determine the complex refractive index for all ATR measurements. The averaged complex refractive index function shows excellent agreement with that obtained through ATR spectroscopic ellipsometry.

Applied SpectroscopyVol. 79(6)
Leibniz Institute of Photonic Technology (DE), Friedrich Schiller University Jena (DE)
Openalex Percentile: Top 7%
Spectroscopy and Quantum Chemical Studies
3.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.