High‐Resolution Cortical Dipole Imaging Using <scp>EEG</scp> Data Measured with a Small Number of Electrodes Based on the International 10–20 System

Cortical dipole imaging is a common technique utilized to visualize the electrical activity in the brain. However, this technique requires ~100 electrodes from a spatial resolution perspective, resulting in a long preparation time and a heavy burden on the subject. According to the international 10–20 system for recording electroencephalogram signals, 19 electrodes are placed on the scalp of the subject. In this study, high‐resolution cortical dipole imaging using the international 10–20 system was investigated for daily applications. The potential at any position on the scalp was interpolated using multiple regression analysis, and optimum parameter estimation was conducted using the proposed method. The simulation and experimental results suggest that the proposed interpolation method is effective for high‐resolution brain activity imaging when using a limited number of electrodes. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Electrical and Electronic Engineering
Published
2024-10-07
DOI
https://doi.org/10.1002/tee.24215
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High‐Resolution Cortical Dipole Imaging Using EEG Data Measured with a Small Number of Electrodes Based on the International 10–20 System

Junichi Hori, Y. Iyama, Kenta Baba
1 citations
IEEJ Transactions on Electrical and Electronic Engineering
Electrical and Bioimpedance Tomography
0.21
article

High‐Resolution Cortical Dipole Imaging Using EEG Data Measured with a Small Number of Electrodes Based on the International 10–20 System

Junichi Hori, Y. Iyama, Kenta Baba
article en
1 citations

Abstract

Cortical dipole imaging is a common technique utilized to visualize the electrical activity in the brain. However, this technique requires ~100 electrodes from a spatial resolution perspective, resulting in a long preparation time and a heavy burden on the subject. According to the international 10–20 system for recording electroencephalogram signals, 19 electrodes are placed on the scalp of the subject. In this study, high‐resolution cortical dipole imaging using the international 10–20 system was investigated for daily applications. The potential at any position on the scalp was interpolated using multiple regression analysis, and optimum parameter estimation was conducted using the proposed method. The simulation and experimental results suggest that the proposed interpolation method is effective for high‐resolution brain activity imaging when using a limited number of electrodes. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

IEEJ Transactions on Electrical and Electronic EngineeringVol. 20(3)
Niigata University (JP)
Openalex Percentile: Top 47%
Electrical and Bioimpedance Tomography
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.