Near-Fault Earthquake-Induced Vibration Control of a Supertall Benchmark Building Using an Inerter-Assisted Compliant Liquid Damper

To exploit the potential of liquid dampers for vibration control of supertall buildings, it is essential to install sizable liquid tanks at the top of the building to provide a substantial value of damper mass ratio to achieve significant response reductions. To avoid the practical and structural design difficulties involved in this, this study explored the advantage of utilizing a liquid damper in conjunction with an inerter to capitalize on its mass amplification property. To ensure that the liquid damper and the inerter function in tandem, the damper tank must have a compliant connection with the building. In this study, extensive time-domain studies were carried out by modeling a 76-story supertall benchmark building as a multiple-degree-of-freedom lumped mass system and subjecting it to 56 unscaled near-fault earthquake ground motions. The characteristic parameters of the inerter-assisted compliant liquid damper (IA-CLD) are optimized using a genetic algorithm–based multiobjective optimization technique. The means of the maximum interstory drift ratio, along with the peak displacement and acceleration response of the roof, are taken as objective functions. The results indicate that the IA-CLD significantly reduces the probability of exceedance of the set performance limit of the building. The overall performance of the IA-CLD improves as the span of the inerter increases. The optimum inertance ratio converges with its upper limit defined during the optimization. The IA-CLD is quite reliable under a structural stiffness uncertainty of ±20%.

Authors

Institutions

Publication Details

Journal
ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part A Civil Engineering
Published
2024-10-07
DOI
https://doi.org/10.1061/ajrua6.rueng-1358
Citations
7
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
1.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Near-Fault Earthquake-Induced Vibration Control of a Supertall Benchmark Building Using an Inerter-Assisted Compliant Liquid Damper

Anupam Das, Tanmoy Konar, Aparna Ghosh
7 citations
ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part A Civil Engineering
Vibration Control and Rheological Fluids
1.83
article

Near-Fault Earthquake-Induced Vibration Control of a Supertall Benchmark Building Using an Inerter-Assisted Compliant Liquid Damper

Anupam Das, Tanmoy Konar, Aparna Ghosh
article en
7 citations

Abstract

To exploit the potential of liquid dampers for vibration control of supertall buildings, it is essential to install sizable liquid tanks at the top of the building to provide a substantial value of damper mass ratio to achieve significant response reductions. To avoid the practical and structural design difficulties involved in this, this study explored the advantage of utilizing a liquid damper in conjunction with an inerter to capitalize on its mass amplification property. To ensure that the liquid damper and the inerter function in tandem, the damper tank must have a compliant connection with the building. In this study, extensive time-domain studies were carried out by modeling a 76-story supertall benchmark building as a multiple-degree-of-freedom lumped mass system and subjecting it to 56 unscaled near-fault earthquake ground motions. The characteristic parameters of the inerter-assisted compliant liquid damper (IA-CLD) are optimized using a genetic algorithm–based multiobjective optimization technique. The means of the maximum interstory drift ratio, along with the peak displacement and acceleration response of the roof, are taken as objective functions. The results indicate that the IA-CLD significantly reduces the probability of exceedance of the set performance limit of the building. The overall performance of the IA-CLD improves as the span of the inerter increases. The optimum inertance ratio converges with its upper limit defined during the optimization. The IA-CLD is quite reliable under a structural stiffness uncertainty of ±20%.

ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part A Civil EngineeringVol. 10(4)
Indian Institute of Technology Delhi (IN), Indian Institute of Engineering Science and Technology, Shibpur (IN), Maulana Abul Kalam Azad University of Technology, West Bengal (IN)
Climate action
Openalex Percentile: Top 16%
Vibration Control and Rheological Fluids
1.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.