A viable prototype device for air quality and heart rate monitoring using Internet of Things (IoTs)

Air pollution poses a serious risk to everyone's health and well-being, especially the health of young people, the elderly ones, and people who have trouble breathing. All contaminants, such as gases, particulate matter, carbon monoxide, sulfur dioxide and biologically generated particles that are found in the atmosphere are referred to as air pollutants. The traditional ways of monitoring pollution are quite laborious and inefficient enough. It is pertinent to mitigate the excessive air pollution that is detrimental to people's and other living things' health. This bring motivation to carried out the objective of developing a device, an air pollution detector (APD) that monitors and measures both the quality of air and heart rate in a given environment. The IoT devices were used to collate data within a geographical area. The air data collected through MQ 135 sensor were calibrated and processed using Arduino programming language. The LCD module displays the air pollution data with the pulse of heartbeat in beats per minute (BPM) once the air gets denser. The system was tested in different five location on school's campus environments at Lead City University, Ibadan, Nigeria. Two sets of tests were carried out to measure air quality index (AQI) and the pulse. The tests carried out were based on the effect of time of day on AQI and heart rate (HR) in action and resting heart rate (RHR) respectively taking one-hour intervals from 8am to 8pm. The obtained sensitivity results showed that, a higher concentration of air pollution leads to an increase in heart rate and a lower concentration of pollution leads to a decrease in heart rate. Hence, the affordable and eco-friendly developed system has the potential to be used as a tool to explore for researchers, students and bringing awareness on the types of air pollutants for the general public.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.36108/laujet/4202.81.0311
Citations
2
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.41
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A viable prototype device for air quality and heart rate monitoring using Internet of Things (IoTs)

K. E. Ojo, Ayokunle Awelewa, Oluwole Abiodun Adegbola, B. S. Emmanuel
2 citations
Air Quality Monitoring and Forecasting
0.41
article

A viable prototype device for air quality and heart rate monitoring using Internet of Things (IoTs)

K. E. Ojo, Ayokunle Awelewa, Oluwole Abiodun Adegbola, B. S. Emmanuel
article en
2 citations

Abstract

Air pollution poses a serious risk to everyone's health and well-being, especially the health of young people, the elderly ones, and people who have trouble breathing. All contaminants, such as gases, particulate matter, carbon monoxide, sulfur dioxide and biologically generated particles that are found in the atmosphere are referred to as air pollutants. The traditional ways of monitoring pollution are quite laborious and inefficient enough. It is pertinent to mitigate the excessive air pollution that is detrimental to people's and other living things' health. This bring motivation to carried out the objective of developing a device, an air pollution detector (APD) that monitors and measures both the quality of air and heart rate in a given environment. The IoT devices were used to collate data within a geographical area. The air data collected through MQ 135 sensor were calibrated and processed using Arduino programming language. The LCD module displays the air pollution data with the pulse of heartbeat in beats per minute (BPM) once the air gets denser. The system was tested in different five location on school's campus environments at Lead City University, Ibadan, Nigeria. Two sets of tests were carried out to measure air quality index (AQI) and the pulse. The tests carried out were based on the effect of time of day on AQI and heart rate (HR) in action and resting heart rate (RHR) respectively taking one-hour intervals from 8am to 8pm. The obtained sensitivity results showed that, a higher concentration of air pollution leads to an increase in heart rate and a lower concentration of pollution leads to a decrease in heart rate. Hence, the affordable and eco-friendly developed system has the potential to be used as a tool to explore for researchers, students and bringing awareness on the types of air pollutants for the general public.

Vol. 18(3)
Covenant University (NG), Ladoke Akintola University of Technology (NG), Lead City University (NG)
Openalex Percentile: Top 41%
Air Quality Monitoring and Forecasting
0.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.