Data Analysis to Assess and Improve the Operation of Combined Sewer Overflow Structures with Static Optimization
Combined sewer systems contain flow-dividing structures. These provide retention volumes for hydraulic overloads of the sewer system during storm weather events. The operation of these structures can be optimized by adjusting the continuous flows of their flow control devices. With that, it is possible to improve the efficiency of entire systems in terms of emissions by making better use of the existing volumetric capacity. To assess this potential, water level measurements from CSO storage tanks were analyzed using statistical methods such as scaling, deviation, and frequency analysis. The data analysis also obtained meta information, such as weir heights and continuation flows, which were more accurate than manual measurements taken in the tank or from construction plans. The main steps involved data preprocessing and meta data gathering to separate events and evaluate the system’s basic functioning. This was followed by optimization of the settings of the flow control devices using an emulator and a genetic algorithm.