Real-time Blood Pressure Prediction on Wearables with Edge-Based DNNs: A Co-Design Approach

This paper presents the hardware realization of a real-time blood pressure (BP) prediction model for wearable devices, utilizing long short-term memory (LSTM) deep neural networks (DNNs). The proposed system uses both electrocardiogram (ECG) and photoplethysmogram (PPG) signal values for BP prediction. It aims to address the limitations of traditional BP measurement methods, providing a low error, minimal computational overhead, and a more accurate and convenient alternative system for individuals with hypertension or those at risk for cardiovascular diseases. The utilization of a split matrix approach leads to a reduction in hardware complexity across the entire system. This technique involves breaking down the larger weight matrices used in the computations of DNNs into smaller matrices. This fragmentation results in a decrease in the complexity of the hardware responsible for performing matrix vector multiplications (MVMs) within LSTMs. The resultant architecture of the predictive model gains several advantages, including a lowered level of complexity in terms of the space occupied by individual cells, decreased processing delay, and reduced power consumption. Furthermore, this approach enables the achievement of a notably improved minimum achievable clock period of 2.972 ns. This prediction model can operate locally on wearable devices, reducing the reliance on cloud computing and improving privacy and security. The performance evaluations are carried out using both analytical and implementation results. The results indicate that the proposed model can be practically applied to real-world problems and can potentially enhance the accuracy of various machine-learning tasks.

Authors

Institutions

Publication Details

Journal
ACM Transactions on Design Automation of Electronic Systems
Published
2024-10-07
DOI
https://doi.org/10.1145/3699512
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time Blood Pressure Prediction on Wearables with Edge-Based DNNs: A Co-Design Approach

Tresa Joseph, T. S. Bindiya
2 citations
ACM Transactions on Design Automation of Electronic Systems
Non-Invasive Vital Sign Monitoring
0.37
article

Real-time Blood Pressure Prediction on Wearables with Edge-Based DNNs: A Co-Design Approach

Tresa Joseph, T. S. Bindiya
article en
2 citations

Abstract

This paper presents the hardware realization of a real-time blood pressure (BP) prediction model for wearable devices, utilizing long short-term memory (LSTM) deep neural networks (DNNs). The proposed system uses both electrocardiogram (ECG) and photoplethysmogram (PPG) signal values for BP prediction. It aims to address the limitations of traditional BP measurement methods, providing a low error, minimal computational overhead, and a more accurate and convenient alternative system for individuals with hypertension or those at risk for cardiovascular diseases. The utilization of a split matrix approach leads to a reduction in hardware complexity across the entire system. This technique involves breaking down the larger weight matrices used in the computations of DNNs into smaller matrices. This fragmentation results in a decrease in the complexity of the hardware responsible for performing matrix vector multiplications (MVMs) within LSTMs. The resultant architecture of the predictive model gains several advantages, including a lowered level of complexity in terms of the space occupied by individual cells, decreased processing delay, and reduced power consumption. Furthermore, this approach enables the achievement of a notably improved minimum achievable clock period of 2.972 ns. This prediction model can operate locally on wearable devices, reducing the reliance on cloud computing and improving privacy and security. The performance evaluations are carried out using both analytical and implementation results. The results indicate that the proposed model can be practically applied to real-world problems and can potentially enhance the accuracy of various machine-learning tasks.

ACM Transactions on Design Automation of Electronic SystemsVol. 30(1)
National Institute of Technology Calicut (IN)
Affordable and clean energy
Openalex Percentile: Top 43%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.