Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

<b>Background:</b> It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. <b>Method:</b> Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon's thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. <b>Results:</b> The measurements at 6 cm from the calcaneal insertion showed α = 0.996, α = 0.998 for measurements at 4 cm using manual acquisition, and α = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (α = 0.999 and α = 1.000). <b>Conclusions:</b> The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon's thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound's applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon's thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-10-05
DOI
https://doi.org/10.3390/diagnostics14192221
Citations
3
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

Luis M. Gordillo-Fernández, Gabriel Domínguez-Maldonado, Raquel Alabau‐Dasi, Ana Belén Ortega‐Ávila et al.
3 citations
Diagnostics
Tendon Structure and Treatment
1.43
article

Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

Luis M. Gordillo-Fernández, Gabriel Domínguez-Maldonado, Raquel Alabau‐Dasi, Ana Belén Ortega‐Ávila, Mercedes Ortiz-Romero, Gabriel Gijón-Noguerón, Juan Manuel Melchor Rodríguez
article en
3 citations

Abstract

<b>Background:</b> It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. <b>Method:</b> Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon's thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. <b>Results:</b> The measurements at 6 cm from the calcaneal insertion showed α = 0.996, α = 0.998 for measurements at 4 cm using manual acquisition, and α = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (α = 0.999 and α = 1.000). <b>Conclusions:</b> The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon's thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound's applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon's thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.

DiagnosticsVol. 14(19)
Universidad de Granada (ES), Instituto de Investigación Biosanitaria de Granada (ES), Instituto de Investigación Biomédica de Málaga (ES), Universidad de Sevilla (ES), Universidad de Málaga (ES)
Good health and well-being
Openalex Percentile: Top 20%
Tendon Structure and Treatment
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.