Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT

<b>Objectives</b>: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. <b>Materials & Methods</b>: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. <b>Results</b>: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (<i>p</i> < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (<i>p</i> < 0.001) except for 50 keV (<i>p</i> > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60-70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. <b>Conclusions</b>: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40-50 keV.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-10-06
DOI
https://doi.org/10.3390/diagnostics14192231
Citations
4
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT

Stephan Waldeck, Aliona Wöhler, Joel Piechotka, M. Völlmecke et al.
4 citations
Diagnostics
Advanced X-ray and CT Imaging
0.74
article

Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT

Stephan Waldeck, Aliona Wöhler, Joel Piechotka, M. Völlmecke, Benjamin V. Becker, Christof Schreyer, Hanns Leonhard Kaatsch, Daniel Dillinger, Sebastian Schaaf, Daniel Overhoff, Laura Kubitscheck, Robert Schwab
article en
4 citations

Abstract

<b>Objectives</b>: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. <b>Materials & Methods</b>: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. <b>Results</b>: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (<i>p</i> < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (<i>p</i> < 0.001) except for 50 keV (<i>p</i> > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60-70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. <b>Conclusions</b>: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40-50 keV.

DiagnosticsVol. 14(19)
Johannes Gutenberg University Mainz (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Universität der Bundeswehr München (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE), BG University Hospital Bergmannsheil Bochum (DE), University Medical Centre Mannheim (DE), Bundeswehrzentralkrankenhaus Koblenz (DE)
Reduced inequalities
Openalex Percentile: Top 32%
Advanced X-ray and CT Imaging
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.