Patients’ effective doses assessment during low-dose computed tomography

Computed tomography has become increasingly common for diagnosing socially significant diseases in recent years. In foreign practice, screening schemes for lung cancer in people belonging to risk categories have been developed and implemented. These schemes have been successfully used over the past 10 years. In this case, “low-dose” scanning protocols are used, which make it possible to perform examination with patient effective dose several times lower compared to standard protocols. Lung cancer screening methods using low-dose computed tomography are beginning to be introduced in the Russian Federation. To ensure the radiation safety of those individuals eligible for inclusion in screening programs or participating in biomedical research testing lung cancer screening, it is necessary to evaluate effective doses from low-dose computed tomography and compare these doses to established radiation dose limits. This study assessed the patients’ effective doses who underwent different types of low-dose computed tomography of chest at two medical organizations. The results of the study show that it is possible to achieve non-exceedance of the current annual effective dose limit of 1 mSv only for patients weighing less than 90 kg. For patients with higher body weight, the minimum effective dose will be in the range of 1.2 – 1.4 mSv. The results of the study indicate the need to make changes to the current regulatory and methodological documents of Rospotrebnadzor to ensure the possibility of using low-dose computed tomography as part of screening for all categories of people.

Authors

Institutions

Publication Details

Journal
Radiacionnaâ gigiena
Published
2024-10-05
DOI
https://doi.org/10.21514/1998-426x-2024-17-3-7-15
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patients’ effective doses assessment during low-dose computed tomography

П. С. Дружинина, А. Д. Ушков, Andrey Nefedov, А. В. Водоватов et al.
Radiacionnaâ gigiena
Radiation Dose and Imaging
article

Patients’ effective doses assessment during low-dose computed tomography

П. С. Дружинина, А. Д. Ушков, Andrey Nefedov, А. В. Водоватов, Л. А. Чипига, И. К. Романович, Г. В. Беркович
article en

Abstract

Computed tomography has become increasingly common for diagnosing socially significant diseases in recent years. In foreign practice, screening schemes for lung cancer in people belonging to risk categories have been developed and implemented. These schemes have been successfully used over the past 10 years. In this case, “low-dose” scanning protocols are used, which make it possible to perform examination with patient effective dose several times lower compared to standard protocols. Lung cancer screening methods using low-dose computed tomography are beginning to be introduced in the Russian Federation. To ensure the radiation safety of those individuals eligible for inclusion in screening programs or participating in biomedical research testing lung cancer screening, it is necessary to evaluate effective doses from low-dose computed tomography and compare these doses to established radiation dose limits. This study assessed the patients’ effective doses who underwent different types of low-dose computed tomography of chest at two medical organizations. The results of the study show that it is possible to achieve non-exceedance of the current annual effective dose limit of 1 mSv only for patients weighing less than 90 kg. For patients with higher body weight, the minimum effective dose will be in the range of 1.2 – 1.4 mSv. The results of the study indicate the need to make changes to the current regulatory and methodological documents of Rospotrebnadzor to ensure the possibility of using low-dose computed tomography as part of screening for all categories of people.

Radiacionnaâ gigienaVol. 17(3)
Ministry of Health of the Russian Federation (RU), Russian Scientific Center of Radiology and Surgical Technologies (RU), Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing (RU), Saint-Petersburg Research Institute of Phthisiopulmonology (RU), Saint Petersburg State Pediatric Medical University (RU)
Reduced inequalities
Openalex Percentile: Top 71%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.