Requirements of the Vapour Barrier in Wood-Frame Walls

This paper examines the water-vapour diffusion resistance (Z-value) of vapour versus wind barriers by determining their Z-value ratio in exterior wood-frame walls thermally insulated with six different materials to prevent mould growth. Using WUFI Pro, the water-vapour diffusion resistance requirements were determined for thermal insulation using mineral wool and biogenic materials: wood fibre, straw, flax, grass, and hemp. Hygrothermal simulations determine the minimum Z-value ratio between these materials with vapour versus wind barriers in temperate and cold climates. Wind barriers with Z-values between 1 and 8 GPa s m2/kg were used in walls with U-values of 0.15 and 0.10 W/m2 K. The indoor moisture load was defined from classes of 1 to 5 with a U-value of 0.15 W/m2 K and classes of 2 and 3 were used for a U-value of 0.10 W/m2 K. The Z-value ratio depends on the Z-values of the wind barrier and thermal insulation material, moisture load class, and U-value. The required Z-value ratio declines with an increased wind-barrier Z-value. The vapour-barrier Z-value approaches a fixed threshold for wind-barrier Z-values approaching lower values (1 GPa s m2/kg) and those approaching higher values (8 GPa s m2/kg), depending on the thermal insulation material. This parameter study examines wind barriers with a Z-value ranging between 1 and 8 GPa s m2/kg, which characterises typical wind barriers used in Denmark For the water-vapour diffusion resistance requirement of the vapour barrier, the Z-value increases for increased moisture load classes and thermally insulated walls with lower U-values. The conversion between the Z-value, the Sd-value, and the water-vapour resistance factor µ can be found in DS/EN ISO 12572:2016.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-10-07
DOI
https://doi.org/10.3390/buildings14103186
Citations
1
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Requirements of the Vapour Barrier in Wood-Frame Walls

Martin Morelli, Torben Valdbjørn Rasmussen, Martin Aagaard Thomsen, Søren Schaldemann Hansen
1 citations
Buildings
Hygrothermal properties of building materials
0.27
article

Requirements of the Vapour Barrier in Wood-Frame Walls

Martin Morelli, Torben Valdbjørn Rasmussen, Martin Aagaard Thomsen, Søren Schaldemann Hansen
article en
1 citations

Abstract

This paper examines the water-vapour diffusion resistance (Z-value) of vapour versus wind barriers by determining their Z-value ratio in exterior wood-frame walls thermally insulated with six different materials to prevent mould growth. Using WUFI Pro, the water-vapour diffusion resistance requirements were determined for thermal insulation using mineral wool and biogenic materials: wood fibre, straw, flax, grass, and hemp. Hygrothermal simulations determine the minimum Z-value ratio between these materials with vapour versus wind barriers in temperate and cold climates. Wind barriers with Z-values between 1 and 8 GPa s m2/kg were used in walls with U-values of 0.15 and 0.10 W/m2 K. The indoor moisture load was defined from classes of 1 to 5 with a U-value of 0.15 W/m2 K and classes of 2 and 3 were used for a U-value of 0.10 W/m2 K. The Z-value ratio depends on the Z-values of the wind barrier and thermal insulation material, moisture load class, and U-value. The required Z-value ratio declines with an increased wind-barrier Z-value. The vapour-barrier Z-value approaches a fixed threshold for wind-barrier Z-values approaching lower values (1 GPa s m2/kg) and those approaching higher values (8 GPa s m2/kg), depending on the thermal insulation material. This parameter study examines wind barriers with a Z-value ranging between 1 and 8 GPa s m2/kg, which characterises typical wind barriers used in Denmark For the water-vapour diffusion resistance requirement of the vapour barrier, the Z-value increases for increased moisture load classes and thermally insulated walls with lower U-values. The conversion between the Z-value, the Sd-value, and the water-vapour resistance factor µ can be found in DS/EN ISO 12572:2016.

BuildingsVol. 14(10)
University College Lillebaelt (DK), Cowi (Denmark) (DK), Aalborg University (DK)
Affordable and clean energy
Openalex Percentile: Top 43%
Hygrothermal properties of building materials
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Requirements of the Vapour Barrier in Wood-Frame Walls — Martin Morelli, Torben Valdbjørn Rasmussen, et al. · Buildings (2024) | TGRS Research Map | TGRS