<i>Operando</i> Electrochemical and Optical Characterization of the Meniscus of Scanning Electrochemical Cell Microscopy (SECCM) Probes

We present a thorough description of the scanning electrochemical cell microscopy (SECCM) meniscus probe, in operation, by combining dual-channel SECCM measurements with <i>in situ</i> interference reflection microscopy (IRM). SECCM is a pipette-based nanoscale characterization tool with an unparalleled capacity for mapping the electrochemical activity of material surfaces, with high precision and at high throughput. In hopping mode, it operates by bringing the electrolyte meniscus, at the scanned pipette tip, in contact with the sample, restricting the probed area each time to a separate, newly wetted site, and forming a small-scale reactor. Each contact area can normally be imaged post-experiment, to inform on the wetted area stability and enable quantitative data interpretation (e.g., to calculate current density). However, the description of meniscus behavior during measurements would be beneficial. Herein, we utilize semi-transparent electrode substrates, to enable the direct optical observation, by IRM, of the meniscus status, with high spatial and temporal resolution, and synchronously to SECCM operation. The surface-sensitive optical method allows us to accurately capture the nature of the miniature electrochemical cell during all phases of the experiment-during approach, meniscus contact, wetting, and pipette withdrawal-and to follow subtle changes while in contact with the electrode substrate. Through the use of a dual-channel probe, we are able to monitor both the ionic current across the meniscus, between quasi-reference counter electrodes (QRCEs) under bias, and between the working electrode surface and the QRCEs. Correlating these electrochemical data and <i>operando</i> optical information via the hybrid SECCM-IRM approach aids the design of experimental protocols, streamlines the interpretation of results, and paints a comprehensive picture of meniscus wetting behavior.

Authors

Institutions

Publication Details

Journal
ACS electrochemistry.
Published
2024-10-07
DOI
https://doi.org/10.1021/acselectrochem.4c00029
Citations
10
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operando Electrochemical and Optical Characterization of the Meniscus of Scanning Electrochemical Cell Microscopy (SECCM) Probes

Frédéric Kanoufi, Gabriel N. Meloni, Jean‐François Lemineur, Paolo Ciocci et al.
10 citations
ACS electrochemistry.
Electrochemical Analysis and Applications
1.72
article

Operando Electrochemical and Optical Characterization of the Meniscus of Scanning Electrochemical Cell Microscopy (SECCM) Probes

Frédéric Kanoufi, Gabriel N. Meloni, Jean‐François Lemineur, Paolo Ciocci, Patrick R. Unwin, Dimitrios Valavanis, Ian J. McPherson
article en
10 citations

Abstract

We present a thorough description of the scanning electrochemical cell microscopy (SECCM) meniscus probe, in operation, by combining dual-channel SECCM measurements with <i>in situ</i> interference reflection microscopy (IRM). SECCM is a pipette-based nanoscale characterization tool with an unparalleled capacity for mapping the electrochemical activity of material surfaces, with high precision and at high throughput. In hopping mode, it operates by bringing the electrolyte meniscus, at the scanned pipette tip, in contact with the sample, restricting the probed area each time to a separate, newly wetted site, and forming a small-scale reactor. Each contact area can normally be imaged post-experiment, to inform on the wetted area stability and enable quantitative data interpretation (e.g., to calculate current density). However, the description of meniscus behavior during measurements would be beneficial. Herein, we utilize semi-transparent electrode substrates, to enable the direct optical observation, by IRM, of the meniscus status, with high spatial and temporal resolution, and synchronously to SECCM operation. The surface-sensitive optical method allows us to accurately capture the nature of the miniature electrochemical cell during all phases of the experiment-during approach, meniscus contact, wetting, and pipette withdrawal-and to follow subtle changes while in contact with the electrode substrate. Through the use of a dual-channel probe, we are able to monitor both the ionic current across the meniscus, between quasi-reference counter electrodes (QRCEs) under bias, and between the working electrode surface and the QRCEs. Correlating these electrochemical data and <i>operando</i> optical information via the hybrid SECCM-IRM approach aids the design of experimental protocols, streamlines the interpretation of results, and paints a comprehensive picture of meniscus wetting behavior.

ACS electrochemistry.Vol. 1(2)
Karlsruhe Institute of Technology (DE), Centre National de la Recherche Scientifique (FR), Loughborough University (GB), Université Paris Cité (FR), University of Warwick (GB), Institute of Catalysis and Petrochemistry (RU), Interfaces Traitements Organisation et Dynamique des Systèmes (FR), Institute of Chemistry (CN)
University of Warwick, European Commission, Fundação de Amparo à Pesquisa do Estado de São Paulo, Centre National de la Recherche Scientifique, Engineering and Physical Sciences Research Council, H2020 Marie Skłodowska-Curie Actions
Openalex Percentile: Top 17%
Electrochemical Analysis and Applications
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.