Comparable bleeding and inflammation outcomes between heparin-coated and uncoated minimal invasive extracorporeal circuits in isolated coronary artery bypass surgery – A double-blinded randomized control trial

ObjectiveMinimally invasive extracorporeal circulation has been shown to be non-inferior or even superior to conventional cardiopulmonary bypass circuits in isolated coronary artery bypass grafting, but there is little evidence whether the addition of a heparin-coated circuit can further reduce the inflammatory response and amount of bleeding in these patients.MethodsA single-center randomized control trial enrolled 49 adult patients scheduled to undergo isolated coronary artery bypass grafting with minimally invasive extracorporeal circulation (MiECC) between January 2015 and December 2018. Patients were randomized 1:1 to either the heparin-coated circuit group, or the uncoated (control) circuit group. The primary outcome was chest tube output 18 h after weaning from MiECC, and secondary outcomes included inflammatory (TNF-α, IL-6, IL-8, IL-10) and complement (C3a, C4d, C5a, sC5b-9) biomarkers, platelet count and function (D2D, TAT, SDC1, PF4), number of transfused blood products, and 30-day survival.ResultsPatients were randomized to undergo myocardial revascularization using heparin-coated circuits (<i>n</i> = 25), and to the uncoated MiECC circuit (<i>n</i> = 24), with comparable baseline demographics. No significant difference was observed in chest tube output and for all secondary outcomes. IL-6 and IL-8 were increased from baseline at 18 h after weaning (effect size 0.29 and 0.05, respectively) and sC5b-9 was lower (effect size 0.11) in the heparin-coated than in the uncoated MiECC, although not significantly different.ConclusionsCompared with an uncoated MiECC circuit, heparin-coated MiECC circuit was not associated with a reduction in postoperative bleeding, transfusion, inflammation, complement activation, and platelet biomarkers, following isolated coronary artery bypass grafting.

Authors

Institutions

Publication Details

Journal
Perfusion
Published
2024-10-07
DOI
https://doi.org/10.1177/02676591241290924
Primary Topic
Cardiac and Coronary Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparable bleeding and inflammation outcomes between heparin-coated and uncoated minimal invasive extracorporeal circuits in isolated coronary artery bypass surgery – A double-blinded randomized control trial

Maks Mihalj, Gabor Erdoes, Alexander Kadner, Robert Rieben et al.
Perfusion
Cardiac and Coronary Surgery Techniques
article

Comparable bleeding and inflammation outcomes between heparin-coated and uncoated minimal invasive extracorporeal circuits in isolated coronary artery bypass surgery – A double-blinded randomized control trial

Maks Mihalj, Gabor Erdoes, Alexander Kadner, Robert Rieben, Markus Huber, Matthias Siepe, Thierry Carrel, Hansjoerg Jenni, Benjamin Kovacic
article en

Abstract

ObjectiveMinimally invasive extracorporeal circulation has been shown to be non-inferior or even superior to conventional cardiopulmonary bypass circuits in isolated coronary artery bypass grafting, but there is little evidence whether the addition of a heparin-coated circuit can further reduce the inflammatory response and amount of bleeding in these patients.MethodsA single-center randomized control trial enrolled 49 adult patients scheduled to undergo isolated coronary artery bypass grafting with minimally invasive extracorporeal circulation (MiECC) between January 2015 and December 2018. Patients were randomized 1:1 to either the heparin-coated circuit group, or the uncoated (control) circuit group. The primary outcome was chest tube output 18 h after weaning from MiECC, and secondary outcomes included inflammatory (TNF-α, IL-6, IL-8, IL-10) and complement (C3a, C4d, C5a, sC5b-9) biomarkers, platelet count and function (D2D, TAT, SDC1, PF4), number of transfused blood products, and 30-day survival.ResultsPatients were randomized to undergo myocardial revascularization using heparin-coated circuits (<i>n</i> = 25), and to the uncoated MiECC circuit (<i>n</i> = 24), with comparable baseline demographics. No significant difference was observed in chest tube output and for all secondary outcomes. IL-6 and IL-8 were increased from baseline at 18 h after weaning (effect size 0.29 and 0.05, respectively) and sC5b-9 was lower (effect size 0.11) in the heparin-coated than in the uncoated MiECC, although not significantly different.ConclusionsCompared with an uncoated MiECC circuit, heparin-coated MiECC circuit was not associated with a reduction in postoperative bleeding, transfusion, inflammation, complement activation, and platelet biomarkers, following isolated coronary artery bypass grafting.

PerfusionVol. 40(5)
University of Bern (CH), University Hospital of Bern (CH), The University of Texas Health Science Center at Houston (US)
Good health and well-being
Openalex Percentile: Top 68%
Cardiac and Coronary Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies