A Wireless and Wearable Multimodal Sensor to Non-Invasively Monitor Transabdominal Placental Oxygen Saturation and Maternal Physiological Signals

Poor placental development and placental defects can lead to adverse pregnancy outcomes such as pre-eclampsia, fetal growth restriction, and stillbirth. This study introduces two sensors, which use a near-infrared spectroscopy (NIRS) technique to measure placental oxygen saturation transabdominally. The first one, an NIRS sensor, is a wearable device consisting of multiple NIRS channels. The second one, a Multimodal sensor, which is an upgraded version of the NIRS sensor, is a wireless and wearable device, integrating a motion sensor and multiple NIRS channels. A pilot clinical study was conducted to assess the feasibility of the two sensors in measuring transabdominal placental oxygenation in 36 pregnant women (n = 12 for the NIRS sensor and n = 24 for the Multimodal sensor). Among these subjects, 4 participants had an uncomplicated pregnancy, and 32 patients had either maternal pre-existing conditions/complications, neonatal complications, and/or placental pathologic abnormalities. The study results indicate that the patients with maternal complicated conditions (69.5 ± 5.4%), placental pathologic abnormalities (69.4 ± 4.9%), and neonatal complications (68.0 ± 5.1%) had statistically significantly lower transabdominal placental oxygenation levels than those with an uncomplicated pregnancy (76.0 ± 4.4%) (<i>F</i> (3,104) = 6.6, <i>p</i> = 0.0004). Additionally, this study shows the capability of the Multimodal sensor in detecting the maternal heart rate and respiratory rate, fetal movements, and uterine contractions. These findings demonstrate the feasibility of the two sensors in the real-time continuous monitoring of transabdominal placental oxygenation to detect at-risk pregnancies and guide timely clinical interventions, thereby improving pregnancy outcomes.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2024-10-07
DOI
https://doi.org/10.3390/bios14100481
Citations
5
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
2.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Wireless and Wearable Multimodal Sensor to Non-Invasively Monitor Transabdominal Placental Oxygen Saturation and Maternal Physiological Signals

Amir Gandjbakhche, Dahiana M. Gallo, Soongho Park, Roberto J. Romero et al.
5 citations
Biosensors
Pregnancy and preeclampsia studies
2.91
article

A Wireless and Wearable Multimodal Sensor to Non-Invasively Monitor Transabdominal Placental Oxygen Saturation and Maternal Physiological Signals

Amir Gandjbakhche, Dahiana M. Gallo, Soongho Park, Roberto J. Romero, Thien Nguyen, Asma Sodager, Jinho Park, Guoyang Luo
article en
5 citations

Abstract

Poor placental development and placental defects can lead to adverse pregnancy outcomes such as pre-eclampsia, fetal growth restriction, and stillbirth. This study introduces two sensors, which use a near-infrared spectroscopy (NIRS) technique to measure placental oxygen saturation transabdominally. The first one, an NIRS sensor, is a wearable device consisting of multiple NIRS channels. The second one, a Multimodal sensor, which is an upgraded version of the NIRS sensor, is a wireless and wearable device, integrating a motion sensor and multiple NIRS channels. A pilot clinical study was conducted to assess the feasibility of the two sensors in measuring transabdominal placental oxygenation in 36 pregnant women (n = 12 for the NIRS sensor and n = 24 for the Multimodal sensor). Among these subjects, 4 participants had an uncomplicated pregnancy, and 32 patients had either maternal pre-existing conditions/complications, neonatal complications, and/or placental pathologic abnormalities. The study results indicate that the patients with maternal complicated conditions (69.5 ± 5.4%), placental pathologic abnormalities (69.4 ± 4.9%), and neonatal complications (68.0 ± 5.1%) had statistically significantly lower transabdominal placental oxygenation levels than those with an uncomplicated pregnancy (76.0 ± 4.4%) (<i>F</i> (3,104) = 6.6, <i>p</i> = 0.0004). Additionally, this study shows the capability of the Multimodal sensor in detecting the maternal heart rate and respiratory rate, fetal movements, and uterine contractions. These findings demonstrate the feasibility of the two sensors in the real-time continuous monitoring of transabdominal placental oxygenation to detect at-risk pregnancies and guide timely clinical interventions, thereby improving pregnancy outcomes.

BiosensorsVol. 14(10)
St. Luke's University Health Network (US), National Institutes of Health (US), Wayne State University (US), University of Michigan (US), Inova Fairfax Hospital (US), National Heart, Lung, and Blood Institute (US), Eunice Kennedy Shriver National Institute of Child Health and Human Development (US), University of Virginia (US), Michigan State University (US)
Eunice Kennedy Shriver National Institute of Child Health and Human Development
Good health and well-being
Openalex Percentile: Top 9%
Pregnancy and preeclampsia studies
2.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.